Uniform Building Code, Volume 7International Conference of Building Officials, 1967 - Building laws |
From inside the book
Results 1-3 of 11
Page 13
... carry out the functions of the Building Department . ( c ) Right of Entry . Upon presentation of proper credentials the Building Official or his duly authorized representatives may enter at reasonable times any building , structure , or ...
... carry out the functions of the Building Department . ( c ) Right of Entry . Upon presentation of proper credentials the Building Official or his duly authorized representatives may enter at reasonable times any building , structure , or ...
Page 65
... carrying masonry or concrete walls in buildings over one story in height shall be fire - protected with not less than one - hour fire protection . EXCEPTION : Fire protection may be omitted from the bottom flange of lintels , shelf ...
... carrying masonry or concrete walls in buildings over one story in height shall be fire - protected with not less than one - hour fire protection . EXCEPTION : Fire protection may be omitted from the bottom flange of lintels , shelf ...
Page 110
... carried around corners at least one support on frame construction . Lath shall be carried down over the foundations at least two inches ( 2 " ) . When the building is of wood frame or metal stud construction with an on - grade concrete ...
... carried around corners at least one support on frame construction . Lath shall be carried down over the foundations at least two inches ( 2 " ) . When the building is of wood frame or metal stud construction with an on - grade concrete ...
Contents
Part Administrative | 11 |
Part IIDefinitions and Abbreviations | 20 |
Part IIIRequirements Based on Occupancy | 27 |
Copyright | |
1 other sections not shown
Other editions - View all
Common terms and phrases
aisle applied approved Area Allowable Building Official building or structure cavity walls cent Chapter 23 coat combustible conform Continued corbeled corridors exceed exit doors exterior exit balcony exterior walls feet Not permitted feet Protected less fire assembly Fire Zone Fire-extinguishing Systems fire-resistive rating fireplace Firestopping flammable liquids foot four inches gauge Group D Occupancies Group H grout Gypsum Lath gypsum wallboard H Occupancies horizontal hour less incombustible installed joists less than four Location on Property locking device Masonry chimneys materials maximum metal lath minimum nails occupant load one-hour fire-resistive construction partitions permitted less portion thereof portland cement plaster pounds per square ramp seats sheathing shingles soffits space spans Special Hazards specified in Chapter specified in Section Stairs stairway stories in height studs supports surface Table thickness tion toilet twelve inches 12 types of construction U.B.C. Standard Uniform Building Code veneer Ventilation Vertical Openings Wood shingles