Uniform Building Code, Volume 7International Conference of Building Officials, 1967 - Building laws |
From inside the book
Results 1-3 of 13
Page 70
... CEMENT MIN . MAX . MASONRY CEMENTS TYPE II DAMP LOOSE AGGREGATE S 2000 1 1/4 1/2 N 750 1 1/2 14 N ( Ma- sonry ) 750 350 1 114 22 1 Not less than 24 and not more than 3 times the sum of the volumes of the cement and lime used . Mortar ...
... CEMENT MIN . MAX . MASONRY CEMENTS TYPE II DAMP LOOSE AGGREGATE S 2000 1 1/4 1/2 N 750 1 1/2 14 N ( Ma- sonry ) 750 350 1 114 22 1 Not less than 24 and not more than 3 times the sum of the volumes of the cement and lime used . Mortar ...
Page 101
... cement plaster . PORTLAND CEMENT PLASTER is a mixture of portland ce- ment , or portland cement and lime and aggregate and other ap- proved materials as specified in this Code . STRIPPING is flat reinforcing units of expanded metal or ...
... cement plaster . PORTLAND CEMENT PLASTER is a mixture of portland ce- ment , or portland cement and lime and aggregate and other ap- proved materials as specified in this Code . STRIPPING is flat reinforcing units of expanded metal or ...
Page 110
... cement plaster . Backing is not required under metal lath or paperbacked wire lath . ( d ) Weather Protection . Building paper shall be installed as required in Section 1707 ( a ) . ( e ) Application of Metal Plaster Bases . The ...
... cement plaster . Backing is not required under metal lath or paperbacked wire lath . ( d ) Weather Protection . Building paper shall be installed as required in Section 1707 ( a ) . ( e ) Application of Metal Plaster Bases . The ...
Contents
Part Administrative | 11 |
Part IIDefinitions and Abbreviations | 20 |
Part IIIRequirements Based on Occupancy | 27 |
Copyright | |
1 other sections not shown
Other editions - View all
Common terms and phrases
aisle applied approved Area Allowable Building Official building or structure cavity walls cent Chapter 23 coat combustible conform Continued corbeled corridors exceed exit doors exterior exit balcony exterior walls feet Not permitted feet Protected less fire assembly Fire Zone Fire-extinguishing Systems fire-resistive rating fireplace Firestopping flammable liquids foot four inches gauge Group D Occupancies Group H grout Gypsum Lath gypsum wallboard H Occupancies horizontal hour less incombustible installed joists less than four Location on Property locking device Masonry chimneys materials maximum metal lath minimum nails occupant load one-hour fire-resistive construction partitions permitted less portion thereof portland cement plaster pounds per square ramp seats sheathing shingles soffits space spans Special Hazards specified in Chapter specified in Section Stairs stairway stories in height studs supports surface Table thickness tion toilet twelve inches 12 types of construction U.B.C. Standard Uniform Building Code veneer Ventilation Vertical Openings Wood shingles