Uniform Building Code, Volume 7International Conference of Building Officials, 1967 - Building laws |
From inside the book
Results 1-3 of 28
Page 12
Application to Existing Buildings ( Continued ) ( b ) Additions , Alterations , and
Repairs : More Than 50 Per Cent . When additions , alterations , or repairs within
any 12 - month period exceed 50 per cent of the value of an existing building or ...
Application to Existing Buildings ( Continued ) ( b ) Additions , Alterations , and
Repairs : More Than 50 Per Cent . When additions , alterations , or repairs within
any 12 - month period exceed 50 per cent of the value of an existing building or ...
Page 29
When openings in exterior walls are required to be protected due to distance
from property line , the sum of the area of such openings shall not exceed 50 per
cent of the total area of the wall in each story . ( c ) Buildings on Same Property
and ...
When openings in exterior walls are required to be protected due to distance
from property line , the sum of the area of such openings shall not exceed 50 per
cent of the total area of the wall in each story . ( c ) Buildings on Same Property
and ...
Page 36
Where public space , streets , or yards more than twenty feet ( 20 ' ) in width
extend along and adjoin two sides of the building , floor areas may be increased
at a rate of one and one - fourth per cent for each foot by which the minimum
width ...
Where public space , streets , or yards more than twenty feet ( 20 ' ) in width
extend along and adjoin two sides of the building , floor areas may be increased
at a rate of one and one - fourth per cent for each foot by which the minimum
width ...
What people are saying - Write a review
We haven't found any reviews in the usual places.
Contents
Part Administrative | 11 |
Part 11Definitions and Abbreviations | 20 |
Part IIlRequirements Based on Occupancy | 27 |
Copyright | |
Other editions - View all
Common terms and phrases
additional aisle Allowable applied approved assembly backing Building Official building or structure ceiling cement cent Chapter chimney coat concrete conform construction Continued corridors covering defined designed Division doors Edition enclosed Enclosure exceed EXCEPTION exit exterior walls finish Fire Zone fire-resistive construction floor floor area foot foundation four framing gauge grade ground Group grout gypsum height horizontal hour inches incombustible increased installed interior joints lath least less limits located masonry materials maximum metal nails occupant load one-hour openings partitions permitted persons placed plaster portion pounds protected repair resistance roof seats separation serving sheathing side solid space spans Special specified in Section square feet Stairs stairway Standard stands story structure studs supports surface Table thereof thickness tion Type Uniform Building Code units unless veneer Ventilation vertical Volume wallboard width wire wood