Uniform Building Code, Volume 7International Conference of Building Officials, 1967 - Building laws |
From inside the book
Results 1-3 of 29
Page 12
... Cent . When additions , alterations , or repairs within any 12 - month period exceed 50 per cent of the value of an existing building or structure , such building or structure shall be made to conform to the requirements for new ...
... Cent . When additions , alterations , or repairs within any 12 - month period exceed 50 per cent of the value of an existing building or structure , such building or structure shall be made to conform to the requirements for new ...
Page 29
... cent of the total area of the wall in each story . ( c ) Buildings on Same Property and Buildings Containing Courts . For the purpose of determining the required wall and opening protection , buildings on the same property and court ...
... cent of the total area of the wall in each story . ( c ) Buildings on Same Property and Buildings Containing Courts . For the purpose of determining the required wall and opening protection , buildings on the same property and court ...
Page 36
... cent for each foot by which the minimum width exceeds twenty feet ( 20 ′ ) , but the increase shall not exceed 50 per cent . 2. Separation on three sides . Where public space , streets , or yards more than twenty feet ( 20 ' ) in width ...
... cent for each foot by which the minimum width exceeds twenty feet ( 20 ′ ) , but the increase shall not exceed 50 per cent . 2. Separation on three sides . Where public space , streets , or yards more than twenty feet ( 20 ' ) in width ...
Contents
Part Administrative | 11 |
Part IIDefinitions and Abbreviations | 20 |
Part IIIRequirements Based on Occupancy | 27 |
Copyright | |
1 other sections not shown
Other editions - View all
Common terms and phrases
aisle applied approved Area Allowable Building Official building or structure cavity walls cent Chapter 23 coat combustible conform Continued corbeled corridors exceed exit doors exterior exit balcony exterior walls feet Not permitted feet Protected less fire assembly Fire Zone Fire-extinguishing Systems fire-resistive rating fireplace Firestopping flammable liquids foot four inches gauge Group D Occupancies Group H grout Gypsum Lath gypsum wallboard H Occupancies horizontal hour less incombustible installed joists less than four Location on Property locking device Masonry chimneys materials maximum metal lath minimum nails occupant load one-hour fire-resistive construction partitions permitted less portion thereof portland cement plaster pounds per square ramp seats sheathing shingles soffits space spans Special Hazards specified in Chapter specified in Section Stairs stairway stories in height studs supports surface Table thickness tion toilet twelve inches 12 types of construction U.B.C. Standard Uniform Building Code veneer Ventilation Vertical Openings Wood shingles