Page 109
... coat may be applied directly to concrete surface . " Approved acoustical plaster may be applied directly to concrete , or over basecoat plaster , beyond the maximum plaster thickness shown . " On concrete ceilings , where the basecoat ...
... coat may be applied directly to concrete surface . " Approved acoustical plaster may be applied directly to concrete , or over basecoat plaster , beyond the maximum plaster thickness shown . " On concrete ceilings , where the basecoat ...
Page 110
... coat work , the first coat shall be brought out to grounds and straightened to a true surface leaving the surface rough to receive the finish coat . For three - coat work , the surface of the first coat shall be scored sufficiently to ...
... coat work , the first coat shall be brought out to grounds and straightened to a true surface leaving the surface rough to receive the finish coat . For three - coat work , the surface of the first coat shall be scored sufficiently to ...
Page 112
... COAT Base Coat Two - coat Work Base Coat Masonry First Coat Lath Second Coat Lath Three - coat Work First and Second Coats Masonry MAXIMUM VOLUME AGGREGATE PER 100 POUNDS NEAT PLASTER2 , 3 ( Cubic Feet ) Damp Loose Sand4 22 3 25 35 3 ...
... COAT Base Coat Two - coat Work Base Coat Masonry First Coat Lath Second Coat Lath Three - coat Work First and Second Coats Masonry MAXIMUM VOLUME AGGREGATE PER 100 POUNDS NEAT PLASTER2 , 3 ( Cubic Feet ) Damp Loose Sand4 22 3 25 35 3 ...
Contents
Part IAdministrative | 11 |
Part IIDefinitions and Abbreviations | 20 |
Part IIIRequirements Based on Occupancy | 27 |
Copyright | |
Other editions - View all
Common terms and phrases
aisle applied approved Area Allowable Building Official building or structure cavity walls cent Chapter 23 coat combustible conform Continued corbeled corridors exceed exit doors exterior exit balcony exterior walls feet 1 hour feet Not permitted feet Protected less fire assembly Fire Zone Fire-extinguishing Systems fire-resistive rating fireplace Firestopping flammable liquids foot four inches G Occupancies gauge Group D Occupancies Group H grout Gypsum Lath gypsum wallboard horizontal hour less incombustible installed joists less than four Location on Property locking device Masonry chimneys materials maximum metal lath minimum nails occupant load one-hour fire-resistive construction partitions permitted less portion thereof pounds per square ramp seats sheathing shingles soffits space spans Special Hazards specified in Chapter specified in Section Stairs stairway stories in height studs supports surface Table thickness tion toilet twelve inches 12 types of construction U.B.C. Standard Uniform Building Code veneer Ventilation Vertical Openings Wood shingles