Page 109
Because masonry and concrete surfaces may vary in plane , thickness of plaster
need not be uniform . 5When applied over a liquid bonding agent , finish coat
may be applied directly to concrete surface . 6 Approved acoustical plaster may
be ...
Because masonry and concrete surfaces may vary in plane , thickness of plaster
need not be uniform . 5When applied over a liquid bonding agent , finish coat
may be applied directly to concrete surface . 6 Approved acoustical plaster may
be ...
Page 110
Plastering with gypsum plaster or portland cement plaster shall be not less than
three coats when applied over metal lath ... For two - coat work , the first coat shall
be brought out to grounds and straightened to a true surface leaving the surface ...
Plastering with gypsum plaster or portland cement plaster shall be not less than
three coats when applied over metal lath ... For two - coat work , the first coat shall
be brought out to grounds and straightened to a true surface leaving the surface ...
Page 112
212 Two - coat Work Base Coat Base Coat First Coat Second Coat First and
Second Coats Gypsum Lath Masonry Lath Lath 25 Three - coat Work / 3 Ma
Masonry Wood fibered gypsum plaster may be mixed in the proportions of 100
pounds of ...
212 Two - coat Work Base Coat Base Coat First Coat Second Coat First and
Second Coats Gypsum Lath Masonry Lath Lath 25 Three - coat Work / 3 Ma
Masonry Wood fibered gypsum plaster may be mixed in the proportions of 100
pounds of ...
What people are saying - Write a review
We haven't found any reviews in the usual places.
Contents
Part Administrative | 11 |
Part 11Definitions and Abbreviations | 20 |
Part IIlRequirements Based on Occupancy | 27 |
Copyright | |
Other editions - View all
Common terms and phrases
additional aisle Allowable applied approved assembly backing Building Official building or structure ceiling cement cent Chapter chimney coat concrete conform construction Continued corridors covering defined designed Division doors Edition enclosed Enclosure exceed EXCEPTION exit exterior walls finish Fire Zone fire-resistive construction floor floor area foot foundation four framing gauge grade ground Group grout gypsum height horizontal hour inches incombustible increased installed interior joints lath least less limits located masonry materials maximum metal nails occupant load one-hour openings partitions permitted persons placed plaster portion pounds protected repair resistance roof seats separation serving sheathing side solid space spans Special specified in Section square feet Stairs stairway Standard stands story structure studs supports surface Table thereof thickness tion Type Uniform Building Code units unless veneer Ventilation vertical Volume wallboard width wire wood