Such toilet rooms in connection with food establishments where food is prepared
, stored , or served , shall have a ... system , which is connected to the light switch
, capable of providing a complete change of air every 15 minutes .
Such toilet rooms in connection with food establishments where food is prepared
, stored , or served , shall have a ... system , which is connected to the light switch
, capable of providing a complete change of air every 15 minutes .
Page 54
Stairs , exits , and smokeproof enclosures shall be as specified in Chapter 25 . All
stairs and exits in Group H Occupancies shall open directly upon a street or alley
or upon a yard or court not less than four feet ( 4 ' ) in width directly connected ...
Stairs , exits , and smokeproof enclosures shall be as specified in Chapter 25 . All
stairs and exits in Group H Occupancies shall open directly upon a street or alley
or upon a yard or court not less than four feet ( 4 ' ) in width directly connected ...
Page 69
18 - A - NUMBER OF NAILS FOR CONNECTING WOOD MEMBERS Groups 1
and J Occupancies CONNECTION BOX OR COMMON Joist to sill or girder - toe
nail Bridging to joist - toe nail 1 x 6 subfloor to joist - face nail 2 - inch subfloor to ...
18 - A - NUMBER OF NAILS FOR CONNECTING WOOD MEMBERS Groups 1
and J Occupancies CONNECTION BOX OR COMMON Joist to sill or girder - toe
nail Bridging to joist - toe nail 1 x 6 subfloor to joist - face nail 2 - inch subfloor to ...
What people are saying - Write a review
We haven't found any reviews in the usual places.
Contents
Part Administrative | 11 |
Part 11Definitions and Abbreviations | 20 |
Part IIlRequirements Based on Occupancy | 27 |
Copyright | |
Other editions - View all
Common terms and phrases
additional aisle Allowable applied approved assembly backing Building Official building or structure ceiling cement cent Chapter chimney coat concrete conform construction Continued corridors covering defined designed Division doors Edition enclosed Enclosure exceed EXCEPTION exit exterior walls finish Fire Zone fire-resistive construction floor floor area foot foundation four framing gauge grade ground Group grout gypsum height horizontal hour inches incombustible increased installed interior joints lath least less limits located masonry materials maximum metal nails occupant load one-hour openings partitions permitted persons placed plaster portion pounds protected repair resistance roof seats separation serving sheathing side solid space spans Special specified in Section square feet Stairs stairway Standard stands story structure studs supports surface Table thereof thickness tion Type Uniform Building Code units unless veneer Ventilation vertical Volume wallboard width wire wood