Page 61
... covered only with a fire- retardant roofing as specified in Section 2203. See Section 104 ( f ) for repairs . 4. Such building may be moved entirely outside the limits of Fire Zone No. 2 . 5. Such building may be demolished . 6 ...
... covered only with a fire- retardant roofing as specified in Section 2203. See Section 104 ( f ) for repairs . 4. Such building may be moved entirely outside the limits of Fire Zone No. 2 . 5. Such building may be demolished . 6 ...
Page 83
... covering provided the frame of the structure is covered with building paper as speci- fied in Section 1707 ( a ) . All shingles or shakes attached to sheath- ings other than wood shall be secured with approved mechanically- bonding ...
... covering provided the frame of the structure is covered with building paper as speci- fied in Section 1707 ( a ) . All shingles or shakes attached to sheath- ings other than wood shall be secured with approved mechanically- bonding ...
Page 89
... covering . 9. Slate shingles . 10. Clay or concrete roof tile . ( b ) Ordinary Roof Covering . An ordinary roof covering shall be any one of the following roofings : 1. Any roof covering listed in Section 2204 ( a ) . 2. Any built - up ...
... covering . 9. Slate shingles . 10. Clay or concrete roof tile . ( b ) Ordinary Roof Covering . An ordinary roof covering shall be any one of the following roofings : 1. Any roof covering listed in Section 2204 ( a ) . 2. Any built - up ...
Contents
Part Administrative | 11 |
Part IIDefinitions and Abbreviations | 20 |
Part IIIRequirements Based on Occupancy | 27 |
Copyright | |
1 other sections not shown
Other editions - View all
Common terms and phrases
aisle applied approved Area Allowable Building Official building or structure cavity walls cent Chapter 23 coat combustible conform Continued corbeled corridors exceed exit doors exterior exit balcony exterior walls feet Not permitted feet Protected less fire assembly Fire Zone Fire-extinguishing Systems fire-resistive rating fireplace Firestopping flammable liquids foot four inches gauge Group D Occupancies Group H grout Gypsum Lath gypsum wallboard H Occupancies horizontal hour less incombustible installed joists less than four Location on Property locking device Masonry chimneys materials maximum metal lath minimum nails occupant load one-hour fire-resistive construction partitions permitted less portion thereof portland cement plaster pounds per square ramp seats sheathing shingles soffits space spans Special Hazards specified in Chapter specified in Section Stairs stairway stories in height studs supports surface Table thickness tion toilet twelve inches 12 types of construction U.B.C. Standard Uniform Building Code veneer Ventilation Vertical Openings Wood shingles