( f ) Repairs : Roof Covering . Not more than 25 per cent of the roof covering of
any building or structure shall be replaced in any 12 - month period unless the
new roof covering is made to conform to the requirements of this Code for new ...
( f ) Repairs : Roof Covering . Not more than 25 per cent of the roof covering of
any building or structure shall be replaced in any 12 - month period unless the
new roof covering is made to conform to the requirements of this Code for new ...
Page 83
Studs or sheathing shall be covered on Exterior Wall the outside face with one
layer of building paper when required Coverings in Section 1707 ( a ) . (
Continued ) Weatherboarding shall have an average thickness in place of not
less than ...
Studs or sheathing shall be covered on Exterior Wall the outside face with one
layer of building paper when required Coverings in Section 1707 ( a ) . (
Continued ) Weatherboarding shall have an average thickness in place of not
less than ...
Page 89
Two layers of 55 - pound mineral surfaced organic fiber felt Roof Coverings split
sheet , or ( Continued ) One layer of 80 - pound mineral surfaced asbestos fiber
felt cap ... An ordinary roof covering shall be any one of the following roofings : 1 .
Two layers of 55 - pound mineral surfaced organic fiber felt Roof Coverings split
sheet , or ( Continued ) One layer of 80 - pound mineral surfaced asbestos fiber
felt cap ... An ordinary roof covering shall be any one of the following roofings : 1 .
What people are saying - Write a review
We haven't found any reviews in the usual places.
Contents
Part Administrative | 11 |
Part 11Definitions and Abbreviations | 20 |
Part IIlRequirements Based on Occupancy | 27 |
Copyright | |
Other editions - View all
Common terms and phrases
additional aisle Allowable applied approved assembly backing Building Official building or structure ceiling cement cent Chapter chimney coat concrete conform construction Continued corridors covering defined designed Division doors Edition enclosed Enclosure exceed EXCEPTION exit exterior walls finish Fire Zone fire-resistive construction floor floor area foot foundation four framing gauge grade ground Group grout gypsum height horizontal hour inches incombustible increased installed interior joints lath least less limits located masonry materials maximum metal nails occupant load one-hour openings partitions permitted persons placed plaster portion pounds protected repair resistance roof seats separation serving sheathing side solid space spans Special specified in Section square feet Stairs stairway Standard stands story structure studs supports surface Table thereof thickness tion Type Uniform Building Code units unless veneer Ventilation vertical Volume wallboard width wire wood