Uniform Building Code, Volume 7International Conference of Building Officials, 1967 - Building laws |
From inside the book
Results 1-3 of 4
Page 68
... diameter can pass through the guardrail . Sec . 1715. Where metal siding or roofing is installed on existing or new construction , provisions shall be made to provide for the bonding and grounding of such building in accordance with the ...
... diameter can pass through the guardrail . Sec . 1715. Where metal siding or roofing is installed on existing or new construction , provisions shall be made to provide for the bonding and grounding of such building in accordance with the ...
Page 100
... diameter steel ties . Where the width of the chimney exceeds forty inches ( 40 ′′ ) , two additional one - half - inch ( 21⁄2 " ) diameter vertical bars shall be provided for each additional flue incorporated in the chimney or for each ...
... diameter steel ties . Where the width of the chimney exceeds forty inches ( 40 ′′ ) , two additional one - half - inch ( 21⁄2 " ) diameter vertical bars shall be provided for each additional flue incorporated in the chimney or for each ...
Page 104
... diameter , mild steel rod1 32 " diameter , mild steel rod1 1/4 " diameter , mild steel rod1 1 " x 1 " mild steel flats2 No. 12 gauge wire No. 10 gauge wire No. 8 gauge wire No. 14 gauge wire No. 12 gauge wire No. 11 gauge wire No. 14 ...
... diameter , mild steel rod1 32 " diameter , mild steel rod1 1/4 " diameter , mild steel rod1 1 " x 1 " mild steel flats2 No. 12 gauge wire No. 10 gauge wire No. 8 gauge wire No. 14 gauge wire No. 12 gauge wire No. 11 gauge wire No. 14 ...
Contents
Part Administrative | 11 |
Part IIDefinitions and Abbreviations | 20 |
Part IIIRequirements Based on Occupancy | 27 |
Copyright | |
1 other sections not shown
Other editions - View all
Common terms and phrases
additional aisle Allowable applied approved assembly backing Building Official building or structure ceiling cement cent Chapter chimney coat concrete conform construction Continued corridors covering defined designed Division doors Edition enclosed Enclosure exceed EXCEPTION exit exterior walls finish Fire Zone fire-resistive construction floor floor area foot foundation four framing gauge grade ground Group grout gypsum height horizontal hour inches incombustible increased installed interior joints lath least less limits located masonry materials maximum metal nails occupant load one-hour openings partitions permitted persons placed plaster portion pounds protected repair resistance roof seats separation serving sheathing side solid space spans Special specified in Section square feet Stairs stairway Standard stands story structure studs supports surface Table thereof thickness tion Type Uniform Building Code units unless veneer Ventilation vertical Volume wallboard width wire wood