Uniform Building Code, Volume 7International Conference of Building Officials, 1967 - Building laws |
From inside the book
Results 1-3 of 4
Page 68
... diameter can pass through the guardrail . Sec . 1715. Where metal siding or roofing is installed on existing or new construction , provisions shall be made to provide for the bonding and grounding of such building in accordance with the ...
... diameter can pass through the guardrail . Sec . 1715. Where metal siding or roofing is installed on existing or new construction , provisions shall be made to provide for the bonding and grounding of such building in accordance with the ...
Page 100
... diameter steel ties . Where the width of the chimney exceeds forty inches ( 40 ′′ ) , two additional one - half - inch ( 1⁄2 " ) diameter vertical bars shall be provided for each additional flue incorporated in the chimney or for each ...
... diameter steel ties . Where the width of the chimney exceeds forty inches ( 40 ′′ ) , two additional one - half - inch ( 1⁄2 " ) diameter vertical bars shall be provided for each additional flue incorporated in the chimney or for each ...
Page 104
... diameter , mild steel rod1 32 " diameter , mild steel rod1 14 " diameter , mild steel rod1 1 " x 1 " mild steel flats2 No. 14 gauge wire 12 No. 12 gauge wire 16 No. 11 gauge wire 8 No. 14 gauge wire No. 16 gauge wire ( 2 loops ) 4 No ...
... diameter , mild steel rod1 32 " diameter , mild steel rod1 14 " diameter , mild steel rod1 1 " x 1 " mild steel flats2 No. 14 gauge wire 12 No. 12 gauge wire 16 No. 11 gauge wire 8 No. 14 gauge wire No. 16 gauge wire ( 2 loops ) 4 No ...
Contents
Part IAdministrative | 11 |
Part IIDefinitions and Abbreviations | 20 |
Part IIIRequirements Based on Occupancy | 27 |
Copyright | |
Other editions - View all
Common terms and phrases
aisle applied approved Area Allowable Building Official building or structure cavity walls cent Chapter 23 coat combustible conform Continued corbeled corridors exceed exit doors exterior exit balcony exterior walls feet 1 hour feet Not permitted feet Protected less fire assembly Fire Zone Fire-extinguishing Systems fire-resistive rating fireplace Firestopping flammable liquids foot four inches G Occupancies gauge Group D Occupancies Group H grout Gypsum Lath gypsum wallboard horizontal hour less incombustible installed joists less than four Location on Property locking device Masonry chimneys materials maximum metal lath minimum nails occupant load one-hour fire-resistive construction partitions permitted less portion thereof pounds per square ramp seats sheathing shingles soffits space spans Special Hazards specified in Chapter specified in Section Stairs stairway stories in height studs supports surface Table thickness tion toilet twelve inches 12 types of construction U.B.C. Standard Uniform Building Code veneer Ventilation Vertical Openings Wood shingles