Page 21
... distance from grade to the floor below is less than the vertical distance from grade to ceiling . ( See " Story . " ) BAY WINDOW is a rectangular , curved , or polygonal window , supported on a foundation extending beyond the main wall ...
... distance from grade to the floor below is less than the vertical distance from grade to ceiling . ( See " Story . " ) BAY WINDOW is a rectangular , curved , or polygonal window , supported on a foundation extending beyond the main wall ...
Page 29
... distance from property line , the sum of the area of such openings shall not exceed 50 per cent of the total area of the wall in each story . ( c ) Buildings on Same Property and Buildings Containing Courts . For the purpose of ...
... distance from property line , the sum of the area of such openings shall not exceed 50 per cent of the total area of the wall in each story . ( c ) Buildings on Same Property and Buildings Containing Courts . For the purpose of ...
Page 139
... Distance to exit . The line of travel to an exit shall be not more than one hundred and fifty feet ( 150 ′ ) . For stands with seats without backrests this distance may be measured by direct line from a seat to the exit from the stand ...
... Distance to exit . The line of travel to an exit shall be not more than one hundred and fifty feet ( 150 ′ ) . For stands with seats without backrests this distance may be measured by direct line from a seat to the exit from the stand ...
Contents
Part Administrative | 11 |
Part IIDefinitions and Abbreviations | 20 |
Part IIIRequirements Based on Occupancy | 27 |
Copyright | |
1 other sections not shown
Other editions - View all
Common terms and phrases
aisle applied approved Area Allowable Building Official building or structure cavity walls cent Chapter 23 coat combustible conform Continued corbeled corridors exceed exit doors exterior exit balcony exterior walls feet Not permitted feet Protected less fire assembly Fire Zone Fire-extinguishing Systems fire-resistive rating fireplace Firestopping flammable liquids foot four inches gauge Group D Occupancies Group H grout Gypsum Lath gypsum wallboard H Occupancies horizontal hour less incombustible installed joists less than four Location on Property locking device Masonry chimneys materials maximum metal lath minimum nails occupant load one-hour fire-resistive construction partitions permitted less portion thereof portland cement plaster pounds per square ramp seats sheathing shingles soffits space spans Special Hazards specified in Chapter specified in Section Stairs stairway stories in height studs supports surface Table thickness tion toilet twelve inches 12 types of construction U.B.C. Standard Uniform Building Code veneer Ventilation Vertical Openings Wood shingles