Uniform Building Code, Volume 7International Conference of Building Officials, 1967 - Building laws |
From inside the book
Results 1-3 of 42
Page 131
... exit passageway . Passageways shall be without openings other than required exits and shall have walls , floors and Exit Courts and Exit Passageways Exit Courts and Exit Passageways ( Continued ) Exit Signs 131 1967 EDITION SECTIONS 2508- ...
... exit passageway . Passageways shall be without openings other than required exits and shall have walls , floors and Exit Courts and Exit Passageways Exit Courts and Exit Passageways ( Continued ) Exit Signs 131 1967 EDITION SECTIONS 2508- ...
Page 132
... exit court and exit passageway shall be at least as wide as the required total width of the tributary exits , such required width being based on the occupant load served . The required width of exit courts or exit passageways shall be ...
... exit court and exit passageway shall be at least as wide as the required total width of the tributary exits , such required width being based on the occupant load served . The required width of exit courts or exit passageways shall be ...
Page 134
International Conference of Building Officials. Seats ( Continued ) Exits : Group A Occupancies Exits : Group B ... Exit . Every Group A Occupancy shall be provided with a main exit . The main exit shall be of sufficient width to ...
International Conference of Building Officials. Seats ( Continued ) Exits : Group A Occupancies Exits : Group B ... Exit . Every Group A Occupancy shall be provided with a main exit . The main exit shall be of sufficient width to ...
Contents
Part Administrative | 11 |
Part IIDefinitions and Abbreviations | 20 |
Part IIIRequirements Based on Occupancy | 27 |
Copyright | |
1 other sections not shown
Other editions - View all
Common terms and phrases
additional aisle Allowable applied approved assembly backing Building Official building or structure ceiling cement cent Chapter chimney coat concrete conform construction Continued corridors covering defined designed Division doors Edition enclosed Enclosure exceed EXCEPTION exit exterior walls finish Fire Zone fire-resistive construction floor floor area foot foundation four framing gauge grade ground Group grout gypsum height horizontal hour inches incombustible increased installed interior joints lath least less limits located masonry materials maximum metal nails occupant load one-hour openings partitions permitted persons placed plaster portion pounds protected repair resistance roof seats separation serving sheathing side solid space spans Special specified in Section square feet Stairs stairway Standard stands story structure studs supports surface Table thereof thickness tion Type Uniform Building Code units unless veneer Ventilation vertical Volume wallboard width wire wood