International Conference of Building Officials. GROUP DESCRIPTION OF OCCUPANCY FIRE ZONE FIRE RESISTANCE OF EXTERIOR WALLS OPENINGS IN EXTERIOR WALLS 4 - Stadiums , reviewing stands , and amusement park structures not included within ...
International Conference of Building Officials. GROUP DESCRIPTION OF OCCUPANCY FIRE ZONE FIRE RESISTANCE OF EXTERIOR WALLS OPENINGS IN EXTERIOR WALLS 4 - Stadiums , reviewing stands , and amusement park structures not included within ...
Page 65
... exterior walls . Such felt or paper shall be applied weatherboard fashion , lapped not less than two inches ( 2 " ) at horizontal joints and not less than six inches ( 6 " ) at vertical joints . Building paper may be omitted in the ...
... exterior walls . Such felt or paper shall be applied weatherboard fashion , lapped not less than two inches ( 2 " ) at horizontal joints and not less than six inches ( 6 " ) at vertical joints . Building paper may be omitted in the ...
Page 66
... walls are required to be fire - resistive due to their location on the property . Parapet walls not less than twelve inches ( 12 " ) in height shall be provided on exterior walls of buildings located in Fire Zone No. 3 when the walls ...
... walls are required to be fire - resistive due to their location on the property . Parapet walls not less than twelve inches ( 12 " ) in height shall be provided on exterior walls of buildings located in Fire Zone No. 3 when the walls ...
Contents
Part Administrative | 11 |
Part IIDefinitions and Abbreviations | 20 |
Part IIIRequirements Based on Occupancy | 27 |
Copyright | |
1 other sections not shown
Other editions - View all
Common terms and phrases
additional aisle Allowable applied approved assembly backing Building Official building or structure ceiling cement cent Chapter chimney coat concrete conform construction Continued corridors covering defined designed Division doors Edition enclosed Enclosure exceed EXCEPTION exit exterior walls finish Fire Zone fire-resistive construction floor floor area foot foundation four framing gauge grade ground Group grout gypsum height horizontal hour inches incombustible increased installed interior joints lath least less limits located masonry materials maximum metal nails occupant load one-hour openings partitions permitted persons placed plaster portion pounds protected repair resistance roof seats separation serving sheathing side solid space spans Special specified in Section square feet Stairs stairway Standard stands story structure studs supports surface Table thereof thickness tion Type Uniform Building Code units unless veneer Ventilation vertical Volume wallboard width wire wood