Page 30
5 - A — WALL AND OPENING PROTECTION OF OCCUPANCIES BASED ON
LOCATION ON PROPERTY TYPES IV AND V ... TYPES I , II , AND III
CONSTRUCTION : Exterior walls and protection of openings shall be as
specified in Sections ...
5 - A — WALL AND OPENING PROTECTION OF OCCUPANCIES BASED ON
LOCATION ON PROPERTY TYPES IV AND V ... TYPES I , II , AND III
CONSTRUCTION : Exterior walls and protection of openings shall be as
specified in Sections ...
Page 65
or approved waterproof paper , shall be applied over studs or sheathing of all
exterior walls . Such felt or paper shall be applied weatherboard fashion , lapped
not less than two inches ( 2 " ) at horizontal joints and not less than six inches ( 6
...
or approved waterproof paper , shall be applied over studs or sheathing of all
exterior walls . Such felt or paper shall be applied weatherboard fashion , lapped
not less than two inches ( 2 " ) at horizontal joints and not less than six inches ( 6
...
Page 66
1 and No . 2 when the walls are required ( Continued ) to be fire - resistive due to
their location on the property . Parapet walls not less than twelve inches ( 12 " ) in
height shall be provided on exterior walls of buildings located in Fire Zone No .
1 and No . 2 when the walls are required ( Continued ) to be fire - resistive due to
their location on the property . Parapet walls not less than twelve inches ( 12 " ) in
height shall be provided on exterior walls of buildings located in Fire Zone No .
What people are saying - Write a review
We haven't found any reviews in the usual places.
Contents
Part Administrative | 11 |
Part 11Definitions and Abbreviations | 20 |
Part IIlRequirements Based on Occupancy | 27 |
Copyright | |
Other editions - View all
Common terms and phrases
additional aisle Allowable applied approved assembly backing Building Official building or structure ceiling cement cent Chapter chimney coat concrete conform construction Continued corridors covering defined designed Division doors Edition enclosed Enclosure exceed EXCEPTION exit exterior walls finish Fire Zone fire-resistive construction floor floor area foot foundation four framing gauge grade ground Group grout gypsum height horizontal hour inches incombustible increased installed interior joints lath least less limits located masonry materials maximum metal nails occupant load one-hour openings partitions permitted persons placed plaster portion pounds protected repair resistance roof seats separation serving sheathing side solid space spans Special specified in Section square feet Stairs stairway Standard stands story structure studs supports surface Table thereof thickness tion Type Uniform Building Code units unless veneer Ventilation vertical Volume wallboard width wire wood