Uniform Building Code, Volume 7International Conference of Building Officials, 1967 - Building laws |
From inside the book
Results 1-3 of 34
Page 30
... less than 5 feet 1 hour elsewhere Not permitted less than 5 feet Protected less than 10 feet 2 hour less than 20 feet 4 - Stadiums , reviewing stands , and amusement park structures not included within Group A nor Divisions 1 , 2 and 3 ...
... less than 5 feet 1 hour elsewhere Not permitted less than 5 feet Protected less than 10 feet 2 hour less than 20 feet 4 - Stadiums , reviewing stands , and amusement park structures not included within Group A nor Divisions 1 , 2 and 3 ...
Page 31
... less than 60 feet Zones Nos . 1 and 2 except as set forth in Sections 1602 ( c ) and 1603 ( c ) . Protected less than 60 feet TABLE NO . 5 - A - Continued FIRE GROUP. D See also Section 902 E See also Section 1002 1 - Mental hospitals ...
... less than 60 feet Zones Nos . 1 and 2 except as set forth in Sections 1602 ( c ) and 1603 ( c ) . Protected less than 60 feet TABLE NO . 5 - A - Continued FIRE GROUP. D See also Section 902 E See also Section 1002 1 - Mental hospitals ...
Page 32
... less than 20 feet 1 hour elsewhere I Dwellings and lodging houses . 2 1 hour 3 1 2 hour less than 20 feet 1 hour ... protected OPENINGS IN EXTERIOR WALLS Not permitted less than 3 feet Protected less than 20 feet Not permitted less than ...
... less than 20 feet 1 hour elsewhere I Dwellings and lodging houses . 2 1 hour 3 1 2 hour less than 20 feet 1 hour ... protected OPENINGS IN EXTERIOR WALLS Not permitted less than 3 feet Protected less than 20 feet Not permitted less than ...
Contents
Part IAdministrative | 11 |
Part IIDefinitions and Abbreviations | 20 |
Part IIIRequirements Based on Occupancy | 27 |
Copyright | |
Other editions - View all
Common terms and phrases
aisle applied approved Area Allowable Building Official building or structure cavity walls cent Chapter 23 coat combustible conform Continued corbeled corridors exceed exit doors exterior exit balcony exterior walls feet 1 hour feet Not permitted feet Protected less fire assembly Fire Zone Fire-extinguishing Systems fire-resistive rating fireplace Firestopping flammable liquids foot four inches G Occupancies gauge Group D Occupancies Group H grout Gypsum Lath gypsum wallboard horizontal hour less incombustible installed joists less than four Location on Property locking device Masonry chimneys materials maximum metal lath minimum nails occupant load one-hour fire-resistive construction partitions permitted less portion thereof pounds per square ramp seats sheathing shingles soffits space spans Special Hazards specified in Chapter specified in Section Stairs stairway stories in height studs supports surface Table thickness tion toilet twelve inches 12 types of construction U.B.C. Standard Uniform Building Code veneer Ventilation Vertical Openings Wood shingles