Uniform Building Code, Volume 7International Conference of Building Officials, 1967 - Building laws |
From inside the book
Results 1-3 of 23
Page 71
... AND FINISH GRADE ( Inches ) OF STORIES 6 6000 18 TABLE NO . 19 - B _
MINIMUM FOUNDATION REQUIREMENTS FOR MASONRY OR CONCRETE
WALLS DEPTH OF FOUNDATION BELOW NATURAL SURFACE OF GROUND
AND ...
... AND FINISH GRADE ( Inches ) OF STORIES 6 6000 18 TABLE NO . 19 - B _
MINIMUM FOUNDATION REQUIREMENTS FOR MASONRY OR CONCRETE
WALLS DEPTH OF FOUNDATION BELOW NATURAL SURFACE OF GROUND
AND ...
Page 109
24 - D — THICKNESS OF PLASTER ' PLASTER BASE FINISHED THICKNESS
OF PLASTER FROM FACE OF LATH , MASONRY ... 5When applied over a liquid
bonding agent , finish coat may be applied directly to concrete surface .
24 - D — THICKNESS OF PLASTER ' PLASTER BASE FINISHED THICKNESS
OF PLASTER FROM FACE OF LATH , MASONRY ... 5When applied over a liquid
bonding agent , finish coat may be applied directly to concrete surface .
Page 116
Gypsum wallboard single layer fire - rated assemblies shall have joints treated
except where the wallboard is to receive a decorative finish such as wood
paneling , battens , acoustical finishes , or any similar application which would be
...
Gypsum wallboard single layer fire - rated assemblies shall have joints treated
except where the wallboard is to receive a decorative finish such as wood
paneling , battens , acoustical finishes , or any similar application which would be
...
What people are saying - Write a review
We haven't found any reviews in the usual places.
Contents
Part Administrative | 11 |
Part 11Definitions and Abbreviations | 20 |
Part IIlRequirements Based on Occupancy | 27 |
Copyright | |
Other editions - View all
Common terms and phrases
additional aisle Allowable applied approved assembly backing Building Official building or structure ceiling cement cent Chapter chimney coat concrete conform construction Continued corridors covering defined designed Division doors Edition enclosed Enclosure exceed EXCEPTION exit exterior walls finish Fire Zone fire-resistive construction floor floor area foot foundation four framing gauge grade ground Group grout gypsum height horizontal hour inches incombustible increased installed interior joints lath least less limits located masonry materials maximum metal nails occupant load one-hour openings partitions permitted persons placed plaster portion pounds protected repair resistance roof seats separation serving sheathing side solid space spans Special specified in Section square feet Stairs stairway Standard stands story structure studs supports surface Table thereof thickness tion Type Uniform Building Code units unless veneer Ventilation vertical Volume wallboard width wire wood