Uniform Building Code, Volume 7International Conference of Building Officials, 1967 - Building laws |
From inside the book
Results 1-3 of 19
Page 42
... Fire - extinguishing Systems Special Hazards Elementary Schools Secondary Schools Colleges and Universities Boys ... doors or windows of the same building shall be protected by a fire assembly having a three- fourths - hour fire ...
... Fire - extinguishing Systems Special Hazards Elementary Schools Secondary Schools Colleges and Universities Boys ... doors or windows of the same building shall be protected by a fire assembly having a three- fourths - hour fire ...
Page 45
... fire doors , the inactive leaf shall be normally secured in the closed position and shall be openable only by the use of a tool . An astragal shall be provided and the active leaf shall be self - closing . CHAPTER 10 REQUIREMENTS FOR ...
... fire doors , the inactive leaf shall be normally secured in the closed position and shall be openable only by the use of a tool . An astragal shall be provided and the active leaf shall be self - closing . CHAPTER 10 REQUIREMENTS FOR ...
Page 56
... Fire- extinguishing Systems Heating Special Hazards twenty square feet ( 120 sq . ft . ) of superficial floor area ... Doors leading into rooms in which volatile flammable liquids are stored or used shall be protected by a fire assembly ...
... Fire- extinguishing Systems Heating Special Hazards twenty square feet ( 120 sq . ft . ) of superficial floor area ... Doors leading into rooms in which volatile flammable liquids are stored or used shall be protected by a fire assembly ...
Contents
Part IAdministrative | 11 |
Part IIDefinitions and Abbreviations | 20 |
Part IIIRequirements Based on Occupancy | 27 |
Copyright | |
Other editions - View all
Common terms and phrases
aisle applied approved Area Allowable Building Official building or structure cavity walls cent Chapter 23 coat combustible conform Continued corbeled corridors exceed exit doors exterior exit balcony exterior walls feet 1 hour feet Not permitted feet Protected less fire assembly Fire Zone Fire-extinguishing Systems fire-resistive rating fireplace Firestopping flammable liquids foot four inches G Occupancies gauge Group D Occupancies Group H grout Gypsum Lath gypsum wallboard horizontal hour less incombustible installed joists less than four Location on Property locking device Masonry chimneys materials maximum metal lath minimum nails occupant load one-hour fire-resistive construction partitions permitted less portion thereof pounds per square ramp seats sheathing shingles soffits space spans Special Hazards specified in Chapter specified in Section Stairs stairway stories in height studs supports surface Table thickness tion toilet twelve inches 12 types of construction U.B.C. Standard Uniform Building Code veneer Ventilation Vertical Openings Wood shingles