Uniform Building Code, Volume 7International Conference of Building Officials, 1967 - Building laws |
From inside the book
Results 1-3 of 21
Page 82
... foot unless ap- proved by the Building Official . EXCEPTION : Veneer units weighing less than three pounds per square foot shall not be limited in dimension or area . 3. Application . In lieu of the design required by Section 2904 ( a ) ...
... foot unless ap- proved by the Building Official . EXCEPTION : Veneer units weighing less than three pounds per square foot shall not be limited in dimension or area . 3. Application . In lieu of the design required by Section 2904 ( a ) ...
Page 84
... FOOT ) FLOOR Maximum Edges Edges Total Live Span4 Blocked Unblocked Load Load ( in inches ) 12/0 12 130 100 0 16/0 16 75 55 0 20/0 20 55 45 0 24/0 24 16 60 45 30/12 30 26 55 40 125 32/16 326 28 507 40 168 36/16 36 30 507 357 168 42/20 ...
... FOOT ) FLOOR Maximum Edges Edges Total Live Span4 Blocked Unblocked Load Load ( in inches ) 12/0 12 130 100 0 16/0 16 75 55 0 20/0 20 55 45 0 24/0 24 16 60 45 30/12 30 26 55 40 125 32/16 326 28 507 40 168 36/16 36 30 507 357 168 42/20 ...
Page 137
... foot of horizontal projection for the structure as a whole . Seat and footboards shall be 120 pounds per lineal foot . The sway force , applied to seats , shall be 24 pounds per lineal foot parallel to the seats , and 10 pounds per lineal ...
... foot of horizontal projection for the structure as a whole . Seat and footboards shall be 120 pounds per lineal foot . The sway force , applied to seats , shall be 24 pounds per lineal foot parallel to the seats , and 10 pounds per lineal ...
Contents
Part Administrative | 11 |
Part IIDefinitions and Abbreviations | 20 |
Part IIIRequirements Based on Occupancy | 27 |
Copyright | |
1 other sections not shown
Other editions - View all
Common terms and phrases
additional aisle Allowable applied approved assembly backing Building Official building or structure ceiling cement cent Chapter chimney coat concrete conform construction Continued corridors covering defined designed Division doors Edition enclosed Enclosure exceed EXCEPTION exit exterior walls finish Fire Zone fire-resistive construction floor floor area foot foundation four framing gauge grade ground Group grout gypsum height horizontal hour inches incombustible increased installed interior joints lath least less limits located masonry materials maximum metal nails occupant load one-hour openings partitions permitted persons placed plaster portion pounds protected repair resistance roof seats separation serving sheathing side solid space spans Special specified in Section square feet Stairs stairway Standard stands story structure studs supports surface Table thereof thickness tion Type Uniform Building Code units unless veneer Ventilation vertical Volume wallboard width wire wood