Uniform Building Code, Volume 7International Conference of Building Officials, 1967 - Building laws |
From inside the book
Results 1-3 of 15
Page 70
Footings and foundations shall be constructed of masonry or concrete and shall
in all cases extend below the frost line . The base areas of all ... Mortar used in
foundation walls and footings shall be Type A mortar as specified in Section 1804
.
Footings and foundations shall be constructed of masonry or concrete and shall
in all cases extend below the frost line . The base areas of all ... Mortar used in
foundation walls and footings shall be Type A mortar as specified in Section 1804
.
Page 71
19 - A - FOUNDATIONS FOR STUD BEARING WALLS MINIMUM
REQUIREMENTS NUMBER WIDTH OF FOOTING ... THICKNESS OF
FOUNDATION WALL ( Inches ) Unit Concrete Masonry DEPTH OF
FOUNDATION BELOW NATURAL ...
19 - A - FOUNDATIONS FOR STUD BEARING WALLS MINIMUM
REQUIREMENTS NUMBER WIDTH OF FOOTING ... THICKNESS OF
FOUNDATION WALL ( Inches ) Unit Concrete Masonry DEPTH OF
FOUNDATION BELOW NATURAL ...
Page 72
Footings feet ( 10 ' ) shall be level or shall be stepped so that both top and (
Continued ) bottom of such foundation are level . ( d ) Footing Design . Except for
special provisions of Section 2808 , 1967 Edition of the Uniform Building Code ...
Footings feet ( 10 ' ) shall be level or shall be stepped so that both top and (
Continued ) bottom of such foundation are level . ( d ) Footing Design . Except for
special provisions of Section 2808 , 1967 Edition of the Uniform Building Code ...
What people are saying - Write a review
We haven't found any reviews in the usual places.
Contents
Part Administrative | 11 |
Part 11Definitions and Abbreviations | 20 |
Part IIlRequirements Based on Occupancy | 27 |
Copyright | |
Other editions - View all
Common terms and phrases
additional aisle Allowable applied approved assembly backing Building Official building or structure ceiling cement cent Chapter chimney coat concrete conform construction Continued corridors covering defined designed Division doors Edition enclosed Enclosure exceed EXCEPTION exit exterior walls finish Fire Zone fire-resistive construction floor floor area foot foundation four framing gauge grade ground Group grout gypsum height horizontal hour inches incombustible increased installed interior joints lath least less limits located masonry materials maximum metal nails occupant load one-hour openings partitions permitted persons placed plaster portion pounds protected repair resistance roof seats separation serving sheathing side solid space spans Special specified in Section square feet Stairs stairway Standard stands story structure studs supports surface Table thereof thickness tion Type Uniform Building Code units unless veneer Ventilation vertical Volume wallboard width wire wood