Uniform Building Code, Volume 7International Conference of Building Officials, 1967 - Building laws |
From inside the book
Results 1-3 of 38
Page 73
... four - inch ( 2 " x 4 " ) studs ; for buildings of three stories , the studding shall be not less than three inches by four inches ( 3 " x 4 " ) or two inches by six inches ( 2 ′′ x 6 ′′ ) to the bottom of the second floor joists , and ...
... four - inch ( 2 " x 4 " ) studs ; for buildings of three stories , the studding shall be not less than three inches by four inches ( 3 " x 4 " ) or two inches by six inches ( 2 ′′ x 6 ′′ ) to the bottom of the second floor joists , and ...
Page 74
... four 16d nails . 7. Separations from chimneys . For clearance space between chimneys and combustible materials , see Section 2302 ( j ) . 8. Top plates . In bearing partitions the top plate shall be dou- bled and lapped at each ...
... four 16d nails . 7. Separations from chimneys . For clearance space between chimneys and combustible materials , see Section 2302 ( j ) . 8. Top plates . In bearing partitions the top plate shall be dou- bled and lapped at each ...
Page 96
... four inches ( 4 " ) of firebrick laid in a solid bed of fire clay mortar with solidly filled head , bed and wall joints , starting not less than two feet ( 2 ' ) below the chimney connector entrance and extending for a distance of at ...
... four inches ( 4 " ) of firebrick laid in a solid bed of fire clay mortar with solidly filled head , bed and wall joints , starting not less than two feet ( 2 ' ) below the chimney connector entrance and extending for a distance of at ...
Contents
Part Administrative | 11 |
Part IIDefinitions and Abbreviations | 20 |
Part IIIRequirements Based on Occupancy | 27 |
Copyright | |
1 other sections not shown
Other editions - View all
Common terms and phrases
aisle applied approved Area Allowable Building Official building or structure cavity walls cent Chapter 23 coat combustible conform Continued corbeled corridors exceed exit doors exterior exit balcony exterior walls feet Not permitted feet Protected less fire assembly Fire Zone Fire-extinguishing Systems fire-resistive rating fireplace Firestopping flammable liquids foot four inches gauge Group D Occupancies Group H grout Gypsum Lath gypsum wallboard H Occupancies horizontal hour less incombustible installed joists less than four Location on Property locking device Masonry chimneys materials maximum metal lath minimum nails occupant load one-hour fire-resistive construction partitions permitted less portion thereof portland cement plaster pounds per square ramp seats sheathing shingles soffits space spans Special Hazards specified in Chapter specified in Section Stairs stairway stories in height studs supports surface Table thickness tion toilet twelve inches 12 types of construction U.B.C. Standard Uniform Building Code veneer Ventilation Vertical Openings Wood shingles