Uniform Building Code, Volume 7International Conference of Building Officials, 1967 - Building laws |
From inside the book
Results 1-3 of 13
Page 40
... greater than thirty - two hundred square feet ( 3200 sq . ft . ) , one - inch ( 1 " ) nominal tight tongue - and - grooved or three - fourths- inch ( 3⁄4 " ) plywood wall covering may be used on the inner side in lieu of fire ...
... greater than thirty - two hundred square feet ( 3200 sq . ft . ) , one - inch ( 1 " ) nominal tight tongue - and - grooved or three - fourths- inch ( 3⁄4 " ) plywood wall covering may be used on the inner side in lieu of fire ...
Page 78
... greater . 4. If the work is stopped for one hour or longer , the horizontal construction joints shall be formed by stopping all tiers at the same elevation and with the grout one inch ( 1 " ) below the top . ( d ) High - lift Grouted ...
... greater . 4. If the work is stopped for one hour or longer , the horizontal construction joints shall be formed by stopping all tiers at the same elevation and with the grout one inch ( 1 " ) below the top . ( d ) High - lift Grouted ...
Page 88
... greater ) MAXIMUM ALLOWABLE SPAN SIZE SPACING OF OF RAFTER RAFTER ( Inches ) ( Inches ) ( Feet and Inches Measured Along the Horizontal Projection ) Group I Group II Group III Group IV2 12 16 2x 4 24 32 12 16 ELE DE 10-0 9-0 7-0 4-0 9-0 ...
... greater ) MAXIMUM ALLOWABLE SPAN SIZE SPACING OF OF RAFTER RAFTER ( Inches ) ( Inches ) ( Feet and Inches Measured Along the Horizontal Projection ) Group I Group II Group III Group IV2 12 16 2x 4 24 32 12 16 ELE DE 10-0 9-0 7-0 4-0 9-0 ...
Contents
Part Administrative | 11 |
Part IIDefinitions and Abbreviations | 20 |
Part IIIRequirements Based on Occupancy | 27 |
Copyright | |
1 other sections not shown
Other editions - View all
Common terms and phrases
additional aisle Allowable applied approved assembly backing Building Official building or structure ceiling cement cent Chapter chimney coat concrete conform construction Continued corridors covering defined designed Division doors Edition enclosed Enclosure exceed EXCEPTION exit exterior walls finish Fire Zone fire-resistive construction floor floor area foot foundation four framing gauge grade ground Group grout gypsum height horizontal hour inches incombustible increased installed interior joints lath least less limits located masonry materials maximum metal nails occupant load one-hour openings partitions permitted persons placed plaster portion pounds protected repair resistance roof seats separation serving sheathing side solid space spans Special specified in Section square feet Stairs stairway Standard stands story structure studs supports surface Table thereof thickness tion Type Uniform Building Code units unless veneer Ventilation vertical Volume wallboard width wire wood