Uniform Building Code, Volume 7International Conference of Building Officials, 1967 - Building laws |
From inside the book
Results 1-3 of 16
Page 101
... gypsum lath and wallboard together and for securing accessories . WIRE BACKING is horizontal strands of tautened ... Gypsum Lath and Wallboard Fiber Insulation Board 47-4-67 Compound , Wallboard Tape and Joint 47-5-67 22-1-67 GYPSUM ...
... gypsum lath and wallboard together and for securing accessories . WIRE BACKING is horizontal strands of tautened ... Gypsum Lath and Wallboard Fiber Insulation Board 47-4-67 Compound , Wallboard Tape and Joint 47-5-67 22-1-67 GYPSUM ...
Page 116
... gypsum wall- board shall occur on the framing members , except those edges and ends which are perpendicular to the framing members . All edges and ends of gypsum wallboard shall be in moderate contact except in concealed spaces where ...
... gypsum wall- board shall occur on the framing members , except those edges and ends which are perpendicular to the framing members . All edges and ends of gypsum wallboard shall be in moderate contact except in concealed spaces where ...
Page 119
... Gypsum lath and plaster , gypsum sheathing board , and gypsum wallboard shall not be used in vertical diaphragms to resist forces imposed by masonry or concrete construction . ( c ) Wall Framing . Framing for vertical diaphragms shall ...
... Gypsum lath and plaster , gypsum sheathing board , and gypsum wallboard shall not be used in vertical diaphragms to resist forces imposed by masonry or concrete construction . ( c ) Wall Framing . Framing for vertical diaphragms shall ...
Contents
Part Administrative | 11 |
Part IIDefinitions and Abbreviations | 20 |
Part IIIRequirements Based on Occupancy | 27 |
Copyright | |
1 other sections not shown
Other editions - View all
Common terms and phrases
aisle applied approved Area Allowable Building Official building or structure cavity walls cent Chapter 23 coat combustible conform Continued corbeled corridors exceed exit doors exterior exit balcony exterior walls feet Not permitted feet Protected less fire assembly Fire Zone Fire-extinguishing Systems fire-resistive rating fireplace Firestopping flammable liquids foot four inches gauge Group D Occupancies Group H grout Gypsum Lath gypsum wallboard H Occupancies horizontal hour less incombustible installed joists less than four Location on Property locking device Masonry chimneys materials maximum metal lath minimum nails occupant load one-hour fire-resistive construction partitions permitted less portion thereof portland cement plaster pounds per square ramp seats sheathing shingles soffits space spans Special Hazards specified in Chapter specified in Section Stairs stairway stories in height studs supports surface Table thickness tion toilet twelve inches 12 types of construction U.B.C. Standard Uniform Building Code veneer Ventilation Vertical Openings Wood shingles