Page 37
... height shall be measured from the highest adjoining sidewalk or ground surface , provided that the height measured from the lowest adjoining surface shall not exceed such maximum height by more than ten feet ( 10 ' ) . The limits set ...
... height shall be measured from the highest adjoining sidewalk or ground surface , provided that the height measured from the lowest adjoining surface shall not exceed such maximum height by more than ten feet ( 10 ' ) . The limits set ...
Page 51
... height or portion thereof shall be considered as a tier . The clear height of a parking tier shall be not less than six feet six inches ( 6'6 " ) except that a lesser clear height may be permitted in mechanical - access open parking ...
... height or portion thereof shall be considered as a tier . The clear height of a parking tier shall be not less than six feet six inches ( 6'6 " ) except that a lesser clear height may be permitted in mechanical - access open parking ...
Page 55
... height the minimum width of the yard shall be increased at the rate of one foot ( 1 ' ) for each additional story . For buildings exceeding 14 stories in height , the required width of yard shall be computed on the basis of 14 stories ...
... height the minimum width of the yard shall be increased at the rate of one foot ( 1 ' ) for each additional story . For buildings exceeding 14 stories in height , the required width of yard shall be computed on the basis of 14 stories ...
Contents
Part Administrative | 11 |
Part IIDefinitions and Abbreviations | 20 |
Part IIIRequirements Based on Occupancy | 27 |
Copyright | |
1 other sections not shown
Other editions - View all
Common terms and phrases
aisle applied approved Area Allowable Building Official building or structure cavity walls cent Chapter 23 coat combustible conform Continued corbeled corridors exceed exit doors exterior exit balcony exterior walls feet Not permitted feet Protected less fire assembly Fire Zone Fire-extinguishing Systems fire-resistive rating fireplace Firestopping flammable liquids foot four inches gauge Group D Occupancies Group H grout Gypsum Lath gypsum wallboard H Occupancies horizontal hour less incombustible installed joists less than four Location on Property locking device Masonry chimneys materials maximum metal lath minimum nails occupant load one-hour fire-resistive construction partitions permitted less portion thereof portland cement plaster pounds per square ramp seats sheathing shingles soffits space spans Special Hazards specified in Chapter specified in Section Stairs stairway stories in height studs supports surface Table thickness tion toilet twelve inches 12 types of construction U.B.C. Standard Uniform Building Code veneer Ventilation Vertical Openings Wood shingles