Uniform Building Code, Volume 7International Conference of Building Officials, 1967 - Building laws |
From inside the book
Results 1-3 of 60
Page 37
... height shall be measured from the highest adjoining sidewalk or ground surface , provided that the height measured from the lowest adjoining surface shall not exceed such maximum height by more than ten feet ( 10 ' ) . The limits set ...
... height shall be measured from the highest adjoining sidewalk or ground surface , provided that the height measured from the lowest adjoining surface shall not exceed such maximum height by more than ten feet ( 10 ' ) . The limits set ...
Page 51
... height or portion thereof shall be considered as a tier . The clear height of a parking tier shall be not less than six feet six inches ( 6'6 " ) except that a lesser clear height may be permitted in mechanical - access open parking ...
... height or portion thereof shall be considered as a tier . The clear height of a parking tier shall be not less than six feet six inches ( 6'6 " ) except that a lesser clear height may be permitted in mechanical - access open parking ...
Page 55
... height the minimum width of the yard shall be increased at the rate of one foot ( 1 ' ) for each additional story . For buildings exceeding 14 stories in height , the required width of yard shall be computed on the basis of 14 stories ...
... height the minimum width of the yard shall be increased at the rate of one foot ( 1 ' ) for each additional story . For buildings exceeding 14 stories in height , the required width of yard shall be computed on the basis of 14 stories ...
Contents
Part Administrative | 11 |
Part IIDefinitions and Abbreviations | 20 |
Part IIIRequirements Based on Occupancy | 27 |
Copyright | |
1 other sections not shown
Other editions - View all
Common terms and phrases
additional aisle Allowable applied approved assembly backing Building Official building or structure ceiling cement cent Chapter chimney coat concrete conform construction Continued corridors covering defined designed Division doors Edition enclosed Enclosure exceed EXCEPTION exit exterior walls finish Fire Zone fire-resistive construction floor floor area foot foundation four framing gauge grade ground Group grout gypsum height horizontal hour inches incombustible increased installed interior joints lath least less limits located masonry materials maximum metal nails occupant load one-hour openings partitions permitted persons placed plaster portion pounds protected repair resistance roof seats separation serving sheathing side solid space spans Special specified in Section square feet Stairs stairway Standard stands story structure studs supports surface Table thereof thickness tion Type Uniform Building Code units unless veneer Ventilation vertical Volume wallboard width wire wood