Uniform Building Code, Volume 7International Conference of Building Officials, 1967 - Building laws |
From inside the book
Results 1-3 of 37
Page 114
... Horizontal Either Direction 16 7 12 1/2 Horizontal Perpendicular 24 7 12 Vertical Either Direction 16 8 12 Horizontal Either Direction 16 7 12 Horizontal Perpendicular 24 7 12 Vertical Either Direction 16 8 12 Fastening Required with ...
... Horizontal Either Direction 16 7 12 1/2 Horizontal Perpendicular 24 7 12 Vertical Either Direction 16 8 12 Horizontal Either Direction 16 7 12 Horizontal Perpendicular 24 7 12 Vertical Either Direction 16 8 12 Fastening Required with ...
Page 117
... Horizontal Perpendicular only 16 3/8 Vertical Either Direction 16 Horizontal Perpendicular only 24 16 24 1/2 Vertical Either Direction 24 Horizontal Perpendicular only 24 Face Ply Nails2 Screws3 7 8 24 16 7 12 8 7 5 % Vertical Either ...
... Horizontal Perpendicular only 16 3/8 Vertical Either Direction 16 Horizontal Perpendicular only 24 16 24 1/2 Vertical Either Direction 24 Horizontal Perpendicular only 24 Face Ply Nails2 Screws3 7 8 24 16 7 12 8 7 5 % Vertical Either ...
Page 130
... horizontal exit may be considered as a required exit . ( b ) Openings . All openings in a separation wall shall be pro- tected by a fire assembly having a fire - resistive rating of not less than one hour . ( c ) Discharge Areas . A ...
... horizontal exit may be considered as a required exit . ( b ) Openings . All openings in a separation wall shall be pro- tected by a fire assembly having a fire - resistive rating of not less than one hour . ( c ) Discharge Areas . A ...
Contents
Part Administrative | 11 |
Part IIDefinitions and Abbreviations | 20 |
Part IIIRequirements Based on Occupancy | 27 |
Copyright | |
1 other sections not shown
Other editions - View all
Common terms and phrases
additional aisle Allowable applied approved assembly backing Building Official building or structure ceiling cement cent Chapter chimney coat concrete conform construction Continued corridors covering defined designed Division doors Edition enclosed Enclosure exceed EXCEPTION exit exterior walls finish Fire Zone fire-resistive construction floor floor area foot foundation four framing gauge grade ground Group grout gypsum height horizontal hour inches incombustible increased installed interior joints lath least less limits located masonry materials maximum metal nails occupant load one-hour openings partitions permitted persons placed plaster portion pounds protected repair resistance roof seats separation serving sheathing side solid space spans Special specified in Section square feet Stairs stairway Standard stands story structure studs supports surface Table thereof thickness tion Type Uniform Building Code units unless veneer Ventilation vertical Volume wallboard width wire wood