Uniform Building Code, Volume 7International Conference of Building Officials, 1967 - Building laws |
From inside the book
Results 1-3 of 72
Page 73
... inches ( 4 " ) of solid masonry or three inches ( 3 " ) of concrete shall be provided between planter boxes and wood stud walls . The masonry or concrete shall extend to a height not less than six inches ( 6 " ) above the outer wall of ...
... inches ( 4 " ) of solid masonry or three inches ( 3 " ) of concrete shall be provided between planter boxes and wood stud walls . The masonry or concrete shall extend to a height not less than six inches ( 6 " ) above the outer wall of ...
Page 96
... inches ( 8 " ) thick , except that stone masonry shall be not less than twelve inches ( 12 " ) thick ; and , in addition , shall be lined with not less than four inches ( 4 " ) of firebrick laid in a solid bed of fire clay mortar with ...
... inches ( 8 " ) thick , except that stone masonry shall be not less than twelve inches ( 12 " ) thick ; and , in addition , shall be lined with not less than four inches ( 4 " ) of firebrick laid in a solid bed of fire clay mortar with ...
Page 99
... inches ( 8 " ) in thickness . Smoke chamber back walls shall be not less than six inches ( 6 ′′ ) in thickness . ( f ) Fireplace Chimneys . Walls of chimneys without flue lining shall be not less than eight inches ( 8 " ) in thickness ...
... inches ( 8 " ) in thickness . Smoke chamber back walls shall be not less than six inches ( 6 ′′ ) in thickness . ( f ) Fireplace Chimneys . Walls of chimneys without flue lining shall be not less than eight inches ( 8 " ) in thickness ...
Contents
Part Administrative | 11 |
Part IIDefinitions and Abbreviations | 20 |
Part IIIRequirements Based on Occupancy | 27 |
Copyright | |
1 other sections not shown
Other editions - View all
Common terms and phrases
aisle applied approved Area Allowable Building Official building or structure cavity walls cent Chapter 23 coat combustible conform Continued corbeled corridors exceed exit doors exterior exit balcony exterior walls feet Not permitted feet Protected less fire assembly Fire Zone Fire-extinguishing Systems fire-resistive rating fireplace Firestopping flammable liquids foot four inches gauge Group D Occupancies Group H grout Gypsum Lath gypsum wallboard H Occupancies horizontal hour less incombustible installed joists less than four Location on Property locking device Masonry chimneys materials maximum metal lath minimum nails occupant load one-hour fire-resistive construction partitions permitted less portion thereof portland cement plaster pounds per square ramp seats sheathing shingles soffits space spans Special Hazards specified in Chapter specified in Section Stairs stairway stories in height studs supports surface Table thickness tion toilet twelve inches 12 types of construction U.B.C. Standard Uniform Building Code veneer Ventilation Vertical Openings Wood shingles