Page 24
4 - 1 - 67 shall be considered incombustible within the meaning of this Section . 2
. Material having a structural base of incombustible material as defined in item No
. 1 above , with a surfacing material not over one - eighth inch ( 18 " ) thick ...
4 - 1 - 67 shall be considered incombustible within the meaning of this Section . 2
. Material having a structural base of incombustible material as defined in item No
. 1 above , with a surfacing material not over one - eighth inch ( 18 " ) thick ...
Page 32
5 - A - Continued FIRE ZONE GROUP DESCRIPTION OF OCCUPANCY Ice
plants , power plants , pumping plants , cold storage , and creameries , factories
and workshops using incombustible and nonexplosive materials . Storage and
sales ...
5 - A - Continued FIRE ZONE GROUP DESCRIPTION OF OCCUPANCY Ice
plants , power plants , pumping plants , cold storage , and creameries , factories
and workshops using incombustible and nonexplosive materials . Storage and
sales ...
Page 82
Anchored veneer shall be supported on footings , foundations , or other
incombustible supports . Where anchored veneer is applied more than twenty
feet ( 20 ' ) above the adjacent ground elevation , it shall be supported by
incombustible ...
Anchored veneer shall be supported on footings , foundations , or other
incombustible supports . Where anchored veneer is applied more than twenty
feet ( 20 ' ) above the adjacent ground elevation , it shall be supported by
incombustible ...
What people are saying - Write a review
We haven't found any reviews in the usual places.
Contents
Part Administrative | 11 |
Part 11Definitions and Abbreviations | 20 |
Part IIlRequirements Based on Occupancy | 27 |
Copyright | |
Other editions - View all
Common terms and phrases
additional aisle Allowable applied approved assembly backing Building Official building or structure ceiling cement cent Chapter chimney coat concrete conform construction Continued corridors covering defined designed Division doors Edition enclosed Enclosure exceed EXCEPTION exit exterior walls finish Fire Zone fire-resistive construction floor floor area foot foundation four framing gauge grade ground Group grout gypsum height horizontal hour inches incombustible increased installed interior joints lath least less limits located masonry materials maximum metal nails occupant load one-hour openings partitions permitted persons placed plaster portion pounds protected repair resistance roof seats separation serving sheathing side solid space spans Special specified in Section square feet Stairs stairway Standard stands story structure studs supports surface Table thereof thickness tion Type Uniform Building Code units unless veneer Ventilation vertical Volume wallboard width wire wood