The floor areas specified in Section 505 may be increased by one of the following
: 1 . Separation on two sides . Where public space , streets , or yards more than
twenty feet ( 20 ' ) in width extend along and adjoin two sides of the building ...
The floor areas specified in Section 505 may be increased by one of the following
: 1 . Separation on two sides . Where public space , streets , or yards more than
twenty feet ( 20 ' ) in width extend along and adjoin two sides of the building ...
Page 37
The area increases permitted in this Subsection may be compounded with that
specified in paragraph numbered 1 , 2 , or ... 5 - D may be increased by one story
if the building is provided with an automatic fire - extinguishing system throughout
...
The area increases permitted in this Subsection may be compounded with that
specified in paragraph numbered 1 , 2 , or ... 5 - D may be increased by one story
if the building is provided with an automatic fire - extinguishing system throughout
...
Page 51
Areas of structures open on four sides may be increased 50 per cent and one tier
in height . ( f ) Location on Property . When located adjacent to interior property
lines , exterior walls shall be of the degree of fire resistance set forth in Table No .
Areas of structures open on four sides may be increased 50 per cent and one tier
in height . ( f ) Location on Property . When located adjacent to interior property
lines , exterior walls shall be of the degree of fire resistance set forth in Table No .
What people are saying - Write a review
We haven't found any reviews in the usual places.
Contents
Part Administrative | 11 |
Part 11Definitions and Abbreviations | 20 |
Part IIlRequirements Based on Occupancy | 27 |
Copyright | |
Other editions - View all
Common terms and phrases
additional aisle Allowable applied approved assembly backing Building Official building or structure ceiling cement cent Chapter chimney coat concrete conform construction Continued corridors covering defined designed Division doors Edition enclosed Enclosure exceed EXCEPTION exit exterior walls finish Fire Zone fire-resistive construction floor floor area foot foundation four framing gauge grade ground Group grout gypsum height horizontal hour inches incombustible increased installed interior joints lath least less limits located masonry materials maximum metal nails occupant load one-hour openings partitions permitted persons placed plaster portion pounds protected repair resistance roof seats separation serving sheathing side solid space spans Special specified in Section square feet Stairs stairway Standard stands story structure studs supports surface Table thereof thickness tion Type Uniform Building Code units unless veneer Ventilation vertical Volume wallboard width wire wood