Uniform Building Code, Volume 7International Conference of Building Officials, 1967 - Building laws |
From inside the book
Results 1-3 of 37
Page 47
... installed provided they are at least seven feet ( 7 ′ ) above the floor . In any room in which volatile flammable liquids are used or stored no device generating a glow or flame capable of igniting gasoline vapor shall be installed or ...
... installed provided they are at least seven feet ( 7 ′ ) above the floor . In any room in which volatile flammable liquids are used or stored no device generating a glow or flame capable of igniting gasoline vapor shall be installed or ...
Page 48
... installed in conformance with U.B.C. Standard No. 10-2-67 , unless the building or portion thereof hous- ing such ... installed in the storage area . EXCEPTION : A One - Hour Fire - Resistive Occupancy Separation is not required where an ...
... installed in conformance with U.B.C. Standard No. 10-2-67 , unless the building or portion thereof hous- ing such ... installed in the storage area . EXCEPTION : A One - Hour Fire - Resistive Occupancy Separation is not required where an ...
Page 110
... installed to pro- vide support for lath and attachments . Gypsum lath or gypsum board shall not be used , except that on horizontal supports of ceilings or roof soffits , it may be used as backing for metal lath or wire lath and ...
... installed to pro- vide support for lath and attachments . Gypsum lath or gypsum board shall not be used , except that on horizontal supports of ceilings or roof soffits , it may be used as backing for metal lath or wire lath and ...
Contents
Part Administrative | 11 |
Part IIDefinitions and Abbreviations | 20 |
Part IIIRequirements Based on Occupancy | 27 |
Copyright | |
1 other sections not shown
Other editions - View all
Common terms and phrases
additional aisle Allowable applied approved assembly backing Building Official building or structure ceiling cement cent Chapter chimney coat concrete conform construction Continued corridors covering defined designed Division doors Edition enclosed Enclosure exceed EXCEPTION exit exterior walls finish Fire Zone fire-resistive construction floor floor area foot foundation four framing gauge grade ground Group grout gypsum height horizontal hour inches incombustible increased installed interior joints lath least less limits located masonry materials maximum metal nails occupant load one-hour openings partitions permitted persons placed plaster portion pounds protected repair resistance roof seats separation serving sheathing side solid space spans Special specified in Section square feet Stairs stairway Standard stands story structure studs supports surface Table thereof thickness tion Type Uniform Building Code units unless veneer Ventilation vertical Volume wallboard width wire wood