Uniform Building Code, Volume 7International Conference of Building Officials, 1967 - Building laws |
From inside the book
Results 1-3 of 26
Page 81
... interior ven- eer may be exempted from the provisions of this Section if approved by the Building Official . ( b ) Limitations . Exterior veneer shall not be attached to wood frame construction at a point more than twenty feet ( 20 ...
... interior ven- eer may be exempted from the provisions of this Section if approved by the Building Official . ( b ) Limitations . Exterior veneer shall not be attached to wood frame construction at a point more than twenty feet ( 20 ...
Page 125
... interior door opening shall be pro- tected as set forth in Table No. 25 - B . Other interior openings , except ventilation louvers equipped with approved automatic fire shutters shall be one - fourth - inch ( 1⁄4 ” ) fixed wire glass ...
... interior door opening shall be pro- tected as set forth in Table No. 25 - B . Other interior openings , except ventilation louvers equipped with approved automatic fire shutters shall be one - fourth - inch ( 1⁄4 ” ) fixed wire glass ...
Page 131
... interior of the building . Access shall be through a vestibule with one wall at least 50 per cent open to the exterior and having an exit door from the interior of the building and an exit door leading to the smokeproof enclosure . In ...
... interior of the building . Access shall be through a vestibule with one wall at least 50 per cent open to the exterior and having an exit door from the interior of the building and an exit door leading to the smokeproof enclosure . In ...
Contents
Part Administrative | 11 |
Part IIDefinitions and Abbreviations | 20 |
Part IIIRequirements Based on Occupancy | 27 |
Copyright | |
1 other sections not shown
Other editions - View all
Common terms and phrases
additional aisle Allowable applied approved assembly backing Building Official building or structure ceiling cement cent Chapter chimney coat concrete conform construction Continued corridors covering defined designed Division doors Edition enclosed Enclosure exceed EXCEPTION exit exterior walls finish Fire Zone fire-resistive construction floor floor area foot foundation four framing gauge grade ground Group grout gypsum height horizontal hour inches incombustible increased installed interior joints lath least less limits located masonry materials maximum metal nails occupant load one-hour openings partitions permitted persons placed plaster portion pounds protected repair resistance roof seats separation serving sheathing side solid space spans Special specified in Section square feet Stairs stairway Standard stands story structure studs supports surface Table thereof thickness tion Type Uniform Building Code units unless veneer Ventilation vertical Volume wallboard width wire wood