All units shall be laid with full shoved mortar joints , and all head , bed , and wall
joints shall be solidly filled with mortar : ( b ) Construction . In each wythe of
bearing and nonbearing walls , except masonry veneer , not less than 75 per
cent of ...
All units shall be laid with full shoved mortar joints , and all head , bed , and wall
joints shall be solidly filled with mortar : ( b ) Construction . In each wythe of
bearing and nonbearing walls , except masonry veneer , not less than 75 per
cent of ...
Page 83
Horizontal joints in the weatherboarding shall be tongued and grooved or
shiplapped joints , or such weatherboarding shall be laid shingle fashion and
lapped not less than one - half inch ( 1 / 2 " ) . Siding patterns known as rustic ,
drop siding ...
Horizontal joints in the weatherboarding shall be tongued and grooved or
shiplapped joints , or such weatherboarding shall be laid shingle fashion and
lapped not less than one - half inch ( 1 / 2 " ) . Siding patterns known as rustic ,
drop siding ...
Page 116
24 - H . The face ply of gypsum wallboard may be applied with gypsum wallboard
joint compound or approved adhesive ... 24 - H . When the face ply is installed
with joint compound or adhesive , the joints of the face ply need not occur on ...
24 - H . The face ply of gypsum wallboard may be applied with gypsum wallboard
joint compound or approved adhesive ... 24 - H . When the face ply is installed
with joint compound or adhesive , the joints of the face ply need not occur on ...
What people are saying - Write a review
We haven't found any reviews in the usual places.
Contents
Part Administrative | 11 |
Part 11Definitions and Abbreviations | 20 |
Part IIlRequirements Based on Occupancy | 27 |
Copyright | |
Other editions - View all
Common terms and phrases
additional aisle Allowable applied approved assembly backing Building Official building or structure ceiling cement cent Chapter chimney coat concrete conform construction Continued corridors covering defined designed Division doors Edition enclosed Enclosure exceed EXCEPTION exit exterior walls finish Fire Zone fire-resistive construction floor floor area foot foundation four framing gauge grade ground Group grout gypsum height horizontal hour inches incombustible increased installed interior joints lath least less limits located masonry materials maximum metal nails occupant load one-hour openings partitions permitted persons placed plaster portion pounds protected repair resistance roof seats separation serving sheathing side solid space spans Special specified in Section square feet Stairs stairway Standard stands story structure studs supports surface Table thereof thickness tion Type Uniform Building Code units unless veneer Ventilation vertical Volume wallboard width wire wood