Uniform Building Code, Volume 7International Conference of Building Officials, 1967 - Building laws |
From inside the book
Results 1-3 of 8
Page 77
... laid contigu- ously in mortar . All units shall be laid with full shoved mortar joints , and all head , bed , and wall joints shall be solidly filled with mortar . ( b ) Construction . In each wythe of bearing and nonbearing walls ...
... laid contigu- ously in mortar . All units shall be laid with full shoved mortar joints , and all head , bed , and wall joints shall be solidly filled with mortar . ( b ) Construction . In each wythe of bearing and nonbearing walls ...
Page 78
... laid up and grouted in lifts not to exceed six times the width of the grout space with a maximum of eight inches ( 8 " ) whichever is greater . 4. If the work is stopped for one hour or longer , the horizontal construction joints shall ...
... laid up and grouted in lifts not to exceed six times the width of the grout space with a maximum of eight inches ( 8 " ) whichever is greater . 4. If the work is stopped for one hour or longer , the horizontal construction joints shall ...
Page 92
... laid in straight or staggered courses . Shakes shall be laid with a side lap of not less than one and one - half inches ( 11⁄2 " ) between joints in adjacent courses . Edges shall be parallel within one inch ( 1 " ) . Spacing between ...
... laid in straight or staggered courses . Shakes shall be laid with a side lap of not less than one and one - half inches ( 11⁄2 " ) between joints in adjacent courses . Edges shall be parallel within one inch ( 1 " ) . Spacing between ...
Contents
Part IAdministrative | 11 |
Part IIDefinitions and Abbreviations | 20 |
Part IIIRequirements Based on Occupancy | 27 |
Copyright | |
Other editions - View all
Common terms and phrases
aisle applied approved Area Allowable Building Official building or structure cavity walls cent Chapter 23 coat combustible conform Continued corbeled corridors exceed exit doors exterior exit balcony exterior walls feet 1 hour feet Not permitted feet Protected less fire assembly Fire Zone Fire-extinguishing Systems fire-resistive rating fireplace Firestopping flammable liquids foot four inches G Occupancies gauge Group D Occupancies Group H grout Gypsum Lath gypsum wallboard horizontal hour less incombustible installed joists less than four Location on Property locking device Masonry chimneys materials maximum metal lath minimum nails occupant load one-hour fire-resistive construction partitions permitted less portion thereof pounds per square ramp seats sheathing shingles soffits space spans Special Hazards specified in Chapter specified in Section Stairs stairway stories in height studs supports surface Table thickness tion toilet twelve inches 12 types of construction U.B.C. Standard Uniform Building Code veneer Ventilation Vertical Openings Wood shingles