Uniform Building Code, Volume 7International Conference of Building Officials, 1967 - Building laws |
From inside the book
Results 1-3 of 7
Page 74
... lateral support to the studs . Bridging meeting the require- ments of Section 2002 may serve as required firestopping . 12. Headers . All openings four feet ( 4 ′ ) wide or less in bearing walls shall be provided with headers equivalent ...
... lateral support to the studs . Bridging meeting the require- ments of Section 2002 may serve as required firestopping . 12. Headers . All openings four feet ( 4 ′ ) wide or less in bearing walls shall be provided with headers equivalent ...
Page 77
... lateral support , thickness ( excluding cavity ) , height , and mortar requirements for cavity walls . Sec . 2005. ( a ) General . Grouted masonry is that form of con- Grouted Masonry struction made with brick or solid concrete brick ...
... lateral support , thickness ( excluding cavity ) , height , and mortar requirements for cavity walls . Sec . 2005. ( a ) General . Grouted masonry is that form of con- Grouted Masonry struction made with brick or solid concrete brick ...
Page 81
... lateral loads imposed by the veneer . Consideration shall be given for differential movement of sup- ports including that caused by temperature changes , shrinkage , creep and deflection . 1. Adhered veneer . Adhered veneer and its ...
... lateral loads imposed by the veneer . Consideration shall be given for differential movement of sup- ports including that caused by temperature changes , shrinkage , creep and deflection . 1. Adhered veneer . Adhered veneer and its ...
Contents
Part Administrative | 11 |
Part IIDefinitions and Abbreviations | 20 |
Part IIIRequirements Based on Occupancy | 27 |
Copyright | |
1 other sections not shown
Other editions - View all
Common terms and phrases
additional aisle Allowable applied approved assembly backing Building Official building or structure ceiling cement cent Chapter chimney coat concrete conform construction Continued corridors covering defined designed Division doors Edition enclosed Enclosure exceed EXCEPTION exit exterior walls finish Fire Zone fire-resistive construction floor floor area foot foundation four framing gauge grade ground Group grout gypsum height horizontal hour inches incombustible increased installed interior joints lath least less limits located masonry materials maximum metal nails occupant load one-hour openings partitions permitted persons placed plaster portion pounds protected repair resistance roof seats separation serving sheathing side solid space spans Special specified in Section square feet Stairs stairway Standard stands story structure studs supports surface Table thereof thickness tion Type Uniform Building Code units unless veneer Ventilation vertical Volume wallboard width wire wood