Page 37
... limited if the building is entirely surrounded and adjoined by public space , streets , or yards not less than sixty feet ( 60 ' ) in width . ( c ) Automatic Fire - extinguishing Systems . The area specified in Section 505 may be ...
... limited if the building is entirely surrounded and adjoined by public space , streets , or yards not less than sixty feet ( 60 ' ) in width . ( c ) Automatic Fire - extinguishing Systems . The area specified in Section 505 may be ...
Page 38
... limited to the types of construction set forth in Tables No. 5 - C and No. 5 - D and shall not exceed , in area or height , the limits specified in Sections 505 , 506 , and 507 . EXCEPTION : Division 4 structures of open skeleton frame ...
... limited to the types of construction set forth in Tables No. 5 - C and No. 5 - D and shall not exceed , in area or height , the limits specified in Sections 505 , 506 , and 507 . EXCEPTION : Division 4 structures of open skeleton frame ...
Page 82
... limited by Subsection ( b ) . 2. Unit size limitations . Veneer units shall not exceed thirty - six inches ( 36 " ) in the greatest dimension , nor more than seven hundred and twenty square inches ( 720 sq . in . ) in total area and ...
... limited by Subsection ( b ) . 2. Unit size limitations . Veneer units shall not exceed thirty - six inches ( 36 " ) in the greatest dimension , nor more than seven hundred and twenty square inches ( 720 sq . in . ) in total area and ...
Contents
Part Administrative | 11 |
Part IIDefinitions and Abbreviations | 20 |
Part IIIRequirements Based on Occupancy | 27 |
Copyright | |
1 other sections not shown
Other editions - View all
Common terms and phrases
additional aisle Allowable applied approved assembly backing Building Official building or structure ceiling cement cent Chapter chimney coat concrete conform construction Continued corridors covering defined designed Division doors Edition enclosed Enclosure exceed EXCEPTION exit exterior walls finish Fire Zone fire-resistive construction floor floor area foot foundation four framing gauge grade ground Group grout gypsum height horizontal hour inches incombustible increased installed interior joints lath least less limits located masonry materials maximum metal nails occupant load one-hour openings partitions permitted persons placed plaster portion pounds protected repair resistance roof seats separation serving sheathing side solid space spans Special specified in Section square feet Stairs stairway Standard stands story structure studs supports surface Table thereof thickness tion Type Uniform Building Code units unless veneer Ventilation vertical Volume wallboard width wire wood