Uniform Building Code, Volume 7International Conference of Building Officials, 1967 - Building laws |
From inside the book
Results 1-3 of 16
Page 37
... limited if the building is entirely surrounded and adjoined by public space , streets , or yards not less than sixty feet ( 60 ' ) in width . ( c ) Automatic Fire - extinguishing Systems . The area specified in Section 505 may be ...
... limited if the building is entirely surrounded and adjoined by public space , streets , or yards not less than sixty feet ( 60 ' ) in width . ( c ) Automatic Fire - extinguishing Systems . The area specified in Section 505 may be ...
Page 38
... limited to the types of construction set forth in Tables No. 5 - C and No. 5 - D and shall not exceed , in area or height , the limits specified in Sections 505 , 506 , and 507 . EXCEPTION : Division 4 structures of open skeleton frame ...
... limited to the types of construction set forth in Tables No. 5 - C and No. 5 - D and shall not exceed , in area or height , the limits specified in Sections 505 , 506 , and 507 . EXCEPTION : Division 4 structures of open skeleton frame ...
Page 82
... limited by Subsection ( b ) . 2. Unit size limitations . Veneer units shall not exceed thirty - six inches ( 36 " ) in the greatest dimension , nor more than seven hundred and twenty square inches ( 720 sq . in . ) in total area and ...
... limited by Subsection ( b ) . 2. Unit size limitations . Veneer units shall not exceed thirty - six inches ( 36 " ) in the greatest dimension , nor more than seven hundred and twenty square inches ( 720 sq . in . ) in total area and ...
Contents
Part Administrative | 11 |
Part IIDefinitions and Abbreviations | 20 |
Part IIIRequirements Based on Occupancy | 27 |
Copyright | |
1 other sections not shown
Other editions - View all
Common terms and phrases
aisle applied approved Area Allowable Building Official building or structure cavity walls cent Chapter 23 coat combustible conform Continued corbeled corridors exceed exit doors exterior exit balcony exterior walls feet Not permitted feet Protected less fire assembly Fire Zone Fire-extinguishing Systems fire-resistive rating fireplace Firestopping flammable liquids foot four inches gauge Group D Occupancies Group H grout Gypsum Lath gypsum wallboard H Occupancies horizontal hour less incombustible installed joists less than four Location on Property locking device Masonry chimneys materials maximum metal lath minimum nails occupant load one-hour fire-resistive construction partitions permitted less portion thereof portland cement plaster pounds per square ramp seats sheathing shingles soffits space spans Special Hazards specified in Chapter specified in Section Stairs stairway stories in height studs supports surface Table thickness tion toilet twelve inches 12 types of construction U.B.C. Standard Uniform Building Code veneer Ventilation Vertical Openings Wood shingles