Page 84
... live load plus dead load , 1 / 240th under live load only . Identification Index appears on all panels in the construction grades listed in Footnote No. 1 . * Plywood edges shall have approved tongue and groove joints or shall be ...
... live load plus dead load , 1 / 240th under live load only . Identification Index appears on all panels in the construction grades listed in Footnote No. 1 . * Plywood edges shall have approved tongue and groove joints or shall be ...
Page 85
... live load nor 1 / 240th with dead load and live load . 1Species of lumber are divided into groups as set forth in Table No. 25 - I ° . The allowable spans are based upon stress and deflection criteria set forth in U.B.C. Standard No. 25 ...
... live load nor 1 / 240th with dead load and live load . 1Species of lumber are divided into groups as set forth in Table No. 25 - I ° . The allowable spans are based upon stress and deflection criteria set forth in U.B.C. Standard No. 25 ...
Page 91
... live load nor 1/240 of the span with dead and live load - Without plastered ceiling - not considered . 1Species of lumber are divided into groups as set forth in Table No. 25 - I . Allowable stresses are increased 25 per cent for roof ...
... live load nor 1/240 of the span with dead and live load - Without plastered ceiling - not considered . 1Species of lumber are divided into groups as set forth in Table No. 25 - I . Allowable stresses are increased 25 per cent for roof ...
Contents
Part Administrative | 11 |
Part IIDefinitions and Abbreviations | 20 |
Part IIIRequirements Based on Occupancy | 27 |
Copyright | |
1 other sections not shown
Other editions - View all
Common terms and phrases
aisle applied approved Area Allowable Building Official building or structure cavity walls cent Chapter 23 coat combustible conform Continued corbeled corridors exceed exit doors exterior exit balcony exterior walls feet Not permitted feet Protected less fire assembly Fire Zone Fire-extinguishing Systems fire-resistive rating fireplace Firestopping flammable liquids foot four inches gauge Group D Occupancies Group H grout Gypsum Lath gypsum wallboard H Occupancies horizontal hour less incombustible installed joists less than four Location on Property locking device Masonry chimneys materials maximum metal lath minimum nails occupant load one-hour fire-resistive construction partitions permitted less portion thereof portland cement plaster pounds per square ramp seats sheathing shingles soffits space spans Special Hazards specified in Chapter specified in Section Stairs stairway stories in height studs supports surface Table thickness tion toilet twelve inches 12 types of construction U.B.C. Standard Uniform Building Code veneer Ventilation Vertical Openings Wood shingles