Uniform Building Code, Volume 7International Conference of Building Officials, 1967 - Building laws |
From inside the book
Results 1-3 of 32
Page 21
... located that the vertical distance from grade to the floor below is less than the vertical distance from grade to ceiling . ( See " Story . " ) BAY WINDOW is a rectangular , curved , or polygonal window , supported on a foundation ...
... located that the vertical distance from grade to the floor below is less than the vertical distance from grade to ceiling . ( See " Story . " ) BAY WINDOW is a rectangular , curved , or polygonal window , supported on a foundation ...
Page 39
... located over usable spaces , need not have one - hour fire - resistive protection . Division 3 Occupancies located in a basement or above the first story shall be of not less than one - hour fire - resistive construction . Group B ...
... located over usable spaces , need not have one - hour fire - resistive protection . Division 3 Occupancies located in a basement or above the first story shall be of not less than one - hour fire - resistive construction . Group B ...
Page 66
... located in Fire Zone No. 3 when the walls are required to be fire - resistive due to their location on the property . EXCEPTIONS : Parapets are not required due to fire zone location on the following walls : 1. When the roof ...
... located in Fire Zone No. 3 when the walls are required to be fire - resistive due to their location on the property . EXCEPTIONS : Parapets are not required due to fire zone location on the following walls : 1. When the roof ...
Contents
Part Administrative | 11 |
Part IIDefinitions and Abbreviations | 20 |
Part IIIRequirements Based on Occupancy | 27 |
Copyright | |
1 other sections not shown
Other editions - View all
Common terms and phrases
aisle applied approved Area Allowable Building Official building or structure cavity walls cent Chapter 23 coat combustible conform Continued corbeled corridors exceed exit doors exterior exit balcony exterior walls feet Not permitted feet Protected less fire assembly Fire Zone Fire-extinguishing Systems fire-resistive rating fireplace Firestopping flammable liquids foot four inches gauge Group D Occupancies Group H grout Gypsum Lath gypsum wallboard H Occupancies horizontal hour less incombustible installed joists less than four Location on Property locking device Masonry chimneys materials maximum metal lath minimum nails occupant load one-hour fire-resistive construction partitions permitted less portion thereof portland cement plaster pounds per square ramp seats sheathing shingles soffits space spans Special Hazards specified in Chapter specified in Section Stairs stairway stories in height studs supports surface Table thickness tion toilet twelve inches 12 types of construction U.B.C. Standard Uniform Building Code veneer Ventilation Vertical Openings Wood shingles