Uniform Building Code, Volume 7International Conference of Building Officials, 1967 - Building laws |
From inside the book
Results 1-3 of 28
Page 109
... maximum 1For Fire - resistive Construction , see Tables No. 43 - A , No. 43 - B , * and No. 43 - C . 2When measured from back plane of expanded metal lath , exclusive of ribs , or self - furring lath plaster thickness shall be three ...
... maximum 1For Fire - resistive Construction , see Tables No. 43 - A , No. 43 - B , * and No. 43 - C . 2When measured from back plane of expanded metal lath , exclusive of ribs , or self - furring lath plaster thickness shall be three ...
Page 119
... maximum allowable height to length ratio for the construction in this Section shall be 11⁄2 to 1 . ( e ) Application . End joints of adjacent courses of gypsum lath , gypsum sheathing board or gypsum wallboard sheets shall not occur ...
... maximum allowable height to length ratio for the construction in this Section shall be 11⁄2 to 1 . ( e ) Application . End joints of adjacent courses of gypsum lath , gypsum sheathing board or gypsum wallboard sheets shall not occur ...
Page 138
... maximum rise of treads shall not exceed eight inches ( 8 " ) and the minimum width of the run shall be eleven inches ( 11 " ) . The maximum variations in the width of treads in any one flight shall be not more than three - sixteenths ...
... maximum rise of treads shall not exceed eight inches ( 8 " ) and the minimum width of the run shall be eleven inches ( 11 " ) . The maximum variations in the width of treads in any one flight shall be not more than three - sixteenths ...
Contents
Part Administrative | 11 |
Part IIDefinitions and Abbreviations | 20 |
Part IIIRequirements Based on Occupancy | 27 |
Copyright | |
1 other sections not shown
Other editions - View all
Common terms and phrases
aisle applied approved Area Allowable Building Official building or structure cavity walls cent Chapter 23 coat combustible conform Continued corbeled corridors exceed exit doors exterior exit balcony exterior walls feet Not permitted feet Protected less fire assembly Fire Zone Fire-extinguishing Systems fire-resistive rating fireplace Firestopping flammable liquids foot four inches gauge Group D Occupancies Group H grout Gypsum Lath gypsum wallboard H Occupancies horizontal hour less incombustible installed joists less than four Location on Property locking device Masonry chimneys materials maximum metal lath minimum nails occupant load one-hour fire-resistive construction partitions permitted less portion thereof portland cement plaster pounds per square ramp seats sheathing shingles soffits space spans Special Hazards specified in Chapter specified in Section Stairs stairway stories in height studs supports surface Table thickness tion toilet twelve inches 12 types of construction U.B.C. Standard Uniform Building Code veneer Ventilation Vertical Openings Wood shingles