Uniform Building Code, Volume 7International Conference of Building Officials, 1967 - Building laws |
From inside the book
Results 1-3 of 7
Page 107
International Conference of Building Officials. 3/4 " Rib Expanded Metal Lath TABLE NO . 24 - B ' - TYPES OF LATH - MAXIMUM SPACING OF SUPPORTS —4 5.4 365 365 Welded Wire Lath 1.95 pounds , No. 11 gauge , 2 " x 2 " 1.4 pounds , No. 16 ...
International Conference of Building Officials. 3/4 " Rib Expanded Metal Lath TABLE NO . 24 - B ' - TYPES OF LATH - MAXIMUM SPACING OF SUPPORTS —4 5.4 365 365 Welded Wire Lath 1.95 pounds , No. 11 gauge , 2 " x 2 " 1.4 pounds , No. 16 ...
Page 109
... metal lath , exclusive of ribs , or self - furring lath plaster thickness shall be three - fourths - inch ( 34 " ) minimum . Exterior Lath ( Continued ) Interior Plaster ( Continued from. PLASTER BASE Expanded Metal Lath Wire Lath ...
... metal lath , exclusive of ribs , or self - furring lath plaster thickness shall be three - fourths - inch ( 34 " ) minimum . Exterior Lath ( Continued ) Interior Plaster ( Continued from. PLASTER BASE Expanded Metal Lath Wire Lath ...
Page 110
... metal lath or wire lath and portland cement plaster . Backing is not required under metal lath or paperbacked wire lath . ( d ) Weather Protection . Building paper shall be installed as required in Section 1707 ( a ) . ( e ) Application of ...
... metal lath or wire lath and portland cement plaster . Backing is not required under metal lath or paperbacked wire lath . ( d ) Weather Protection . Building paper shall be installed as required in Section 1707 ( a ) . ( e ) Application of ...
Contents
Part IAdministrative | 11 |
Part IIDefinitions and Abbreviations | 20 |
Part IIIRequirements Based on Occupancy | 27 |
Copyright | |
Other editions - View all
Common terms and phrases
aisle applied approved Area Allowable Building Official building or structure cavity walls cent Chapter 23 coat combustible conform Continued corbeled corridors exceed exit doors exterior exit balcony exterior walls feet 1 hour feet Not permitted feet Protected less fire assembly Fire Zone Fire-extinguishing Systems fire-resistive rating fireplace Firestopping flammable liquids foot four inches G Occupancies gauge Group D Occupancies Group H grout Gypsum Lath gypsum wallboard horizontal hour less incombustible installed joists less than four Location on Property locking device Masonry chimneys materials maximum metal lath minimum nails occupant load one-hour fire-resistive construction partitions permitted less portion thereof pounds per square ramp seats sheathing shingles soffits space spans Special Hazards specified in Chapter specified in Section Stairs stairway stories in height studs supports surface Table thickness tion toilet twelve inches 12 types of construction U.B.C. Standard Uniform Building Code veneer Ventilation Vertical Openings Wood shingles