International Conference of Building Officials. TABLE NO . 18 - B - MORTAR PROPORTIONS ( By Volume ) MINIMUM COMPRESSIVE MORTAR TYPE STRENGTH AT 28 DAYS HYDRATED LIMES OR LIME PUTTY PORTLAND ( p.s.i. ) CEMENT MIN . MAX . MASONRY CEMENTS ...
International Conference of Building Officials. TABLE NO . 18 - B - MORTAR PROPORTIONS ( By Volume ) MINIMUM COMPRESSIVE MORTAR TYPE STRENGTH AT 28 DAYS HYDRATED LIMES OR LIME PUTTY PORTLAND ( p.s.i. ) CEMENT MIN . MAX . MASONRY CEMENTS ...
Page 77
... mortar . All units shall be laid with full shoved mortar joints , and all head , bed , and wall joints shall be solidly filled with mortar . ( b ) Construction . In each wythe of bearing and nonbearing walls , except masonry veneer ...
... mortar . All units shall be laid with full shoved mortar joints , and all head , bed , and wall joints shall be solidly filled with mortar . ( b ) Construction . In each wythe of bearing and nonbearing walls , except masonry veneer ...
Page 96
... mortar with solidly filled head , bed and wall joints , starting not less than two feet ( 2 ' ) below the chimney connector entrance and extending for a distance of at least twenty - five feet ( 25 ' ) above the chimney connector ...
... mortar with solidly filled head , bed and wall joints , starting not less than two feet ( 2 ' ) below the chimney connector entrance and extending for a distance of at least twenty - five feet ( 25 ' ) above the chimney connector ...
Contents
Part IAdministrative | 11 |
Part IIDefinitions and Abbreviations | 20 |
Part IIIRequirements Based on Occupancy | 27 |
Copyright | |
Other editions - View all
Common terms and phrases
aisle applied approved Area Allowable Building Official building or structure cavity walls cent Chapter 23 coat combustible conform Continued corbeled corridors exceed exit doors exterior exit balcony exterior walls feet 1 hour feet Not permitted feet Protected less fire assembly Fire Zone Fire-extinguishing Systems fire-resistive rating fireplace Firestopping flammable liquids foot four inches G Occupancies gauge Group D Occupancies Group H grout Gypsum Lath gypsum wallboard horizontal hour less incombustible installed joists less than four Location on Property locking device Masonry chimneys materials maximum metal lath minimum nails occupant load one-hour fire-resistive construction partitions permitted less portion thereof pounds per square ramp seats sheathing shingles soffits space spans Special Hazards specified in Chapter specified in Section Stairs stairway stories in height studs supports surface Table thickness tion toilet twelve inches 12 types of construction U.B.C. Standard Uniform Building Code veneer Ventilation Vertical Openings Wood shingles