Page 83
Nails shall be so located as to hold the bottom of the weatherboarding or siding
secure and thereby to hold tight the top of the piece below . Where such nailing is
not possible , two nails to each stud shall be used to hold each piece .
Nails shall be so located as to hold the bottom of the weatherboarding or siding
secure and thereby to hold tight the top of the piece below . Where such nailing is
not possible , two nails to each stud shall be used to hold each piece .
Page 114
098 gauge , 1 / 4 " long , Annular ringed 5d , cooler nail 12 Horizontal | Either
Direction Horizontal Perpendicular Vertical Either Direction ... Where the metal
framing has a clinching design formed to receive the nails by two edges of metal
...
098 gauge , 1 / 4 " long , Annular ringed 5d , cooler nail 12 Horizontal | Either
Direction Horizontal Perpendicular Vertical Either Direction ... Where the metal
framing has a clinching design formed to receive the nails by two edges of metal
...
Page 117
Screws3 Nails TABLE NO . 24 - 1 - ALLOWABLE ... 24 - G , use the appropriate
size cooler nail as set forth in Table No . 25 - 24 - A of U . B . C . Standard No . 25
- 24 - 67 . Nails for metal framing shall comply with the provisions of Table No .
Screws3 Nails TABLE NO . 24 - 1 - ALLOWABLE ... 24 - G , use the appropriate
size cooler nail as set forth in Table No . 25 - 24 - A of U . B . C . Standard No . 25
- 24 - 67 . Nails for metal framing shall comply with the provisions of Table No .
What people are saying - Write a review
We haven't found any reviews in the usual places.
Contents
Part Administrative | 11 |
Part 11Definitions and Abbreviations | 20 |
Part IIlRequirements Based on Occupancy | 27 |
Copyright | |
Other editions - View all
Common terms and phrases
additional aisle Allowable applied approved assembly backing Building Official building or structure ceiling cement cent Chapter chimney coat concrete conform construction Continued corridors covering defined designed Division doors Edition enclosed Enclosure exceed EXCEPTION exit exterior walls finish Fire Zone fire-resistive construction floor floor area foot foundation four framing gauge grade ground Group grout gypsum height horizontal hour inches incombustible increased installed interior joints lath least less limits located masonry materials maximum metal nails occupant load one-hour openings partitions permitted persons placed plaster portion pounds protected repair resistance roof seats separation serving sheathing side solid space spans Special specified in Section square feet Stairs stairway Standard stands story structure studs supports surface Table thereof thickness tion Type Uniform Building Code units unless veneer Ventilation vertical Volume wallboard width wire wood