Uniform Building Code, Volume 7International Conference of Building Officials, 1967 - Building laws |
From inside the book
Results 1-3 of 8
Page 83
... nail , or to solid nominal wood sheathing with not less than one line of nails spaced not more than twenty- four inches ( 24 " ) on center in each piece of the weatherboarding or siding . Nails shall be so located as to hold the bottom ...
... nail , or to solid nominal wood sheathing with not less than one line of nails spaced not more than twenty- four inches ( 24 " ) on center in each piece of the weatherboarding or siding . Nails shall be so located as to hold the bottom ...
Page 114
... NAILS TO WOOD ( In Inches ) Nails1 , 3 Screws4 Horizontal Either Direction 16 7 12 1/2 Horizontal Perpendicular 24 7 ... nails by two edges of metal , the nails shall be not less than five - eighths inch ( 5 % " ) longer than the ...
... NAILS TO WOOD ( In Inches ) Nails1 , 3 Screws4 Horizontal Either Direction 16 7 12 1/2 Horizontal Perpendicular 24 7 ... nails by two edges of metal , the nails shall be not less than five - eighths inch ( 5 % " ) longer than the ...
Page 117
... nails not included in Table No. 24 - G , use the appropriate size cooler nail as set forth in Table No. 25-24 - A of U.B.C. Standard No. 25-24-67 . Nails for metal framing shall comply with the provisions of Table No. 24 - G . 3Screws ...
... nails not included in Table No. 24 - G , use the appropriate size cooler nail as set forth in Table No. 25-24 - A of U.B.C. Standard No. 25-24-67 . Nails for metal framing shall comply with the provisions of Table No. 24 - G . 3Screws ...
Contents
Part Administrative | 11 |
Part IIDefinitions and Abbreviations | 20 |
Part IIIRequirements Based on Occupancy | 27 |
Copyright | |
1 other sections not shown
Other editions - View all
Common terms and phrases
additional aisle Allowable applied approved assembly backing Building Official building or structure ceiling cement cent Chapter chimney coat concrete conform construction Continued corridors covering defined designed Division doors Edition enclosed Enclosure exceed EXCEPTION exit exterior walls finish Fire Zone fire-resistive construction floor floor area foot foundation four framing gauge grade ground Group grout gypsum height horizontal hour inches incombustible increased installed interior joints lath least less limits located masonry materials maximum metal nails occupant load one-hour openings partitions permitted persons placed plaster portion pounds protected repair resistance roof seats separation serving sheathing side solid space spans Special specified in Section square feet Stairs stairway Standard stands story structure studs supports surface Table thereof thickness tion Type Uniform Building Code units unless veneer Ventilation vertical Volume wallboard width wire wood