Uniform Building Code, Volume 7International Conference of Building Officials, 1967 - Building laws |
From inside the book
Results 1-3 of 26
Page 120
OCCUPANT LOAD is the total number of persons that may occupy a building or
portion thereof at any one time . PANIC HARDWARE is a bar which extends
across at least one - half the width of each door leaf , which will open the door if ...
OCCUPANT LOAD is the total number of persons that may occupy a building or
portion thereof at any one time . PANIC HARDWARE is a bar which extends
across at least one - half the width of each door leaf , which will open the door if ...
Page 132
Every exit court and exit passageway shall be at least as wide as the required
total width of the tributary exits , such required width being based on the occupant
load served . The required width of exit courts or exit passageways shall be ...
Every exit court and exit passageway shall be at least as wide as the required
total width of the tributary exits , such required width being based on the occupant
load served . The required width of exit courts or exit passageways shall be ...
Page 134
Every auditorium of a Group A Occupancy shall be provided with exits on each
side . The exits on each side of the auditorium shall be of sufficient width to
accommodate one - third of the total occupant load served . Side exits shall open
...
Every auditorium of a Group A Occupancy shall be provided with exits on each
side . The exits on each side of the auditorium shall be of sufficient width to
accommodate one - third of the total occupant load served . Side exits shall open
...
What people are saying - Write a review
We haven't found any reviews in the usual places.
Contents
Part Administrative | 11 |
Part 11Definitions and Abbreviations | 20 |
Part IIlRequirements Based on Occupancy | 27 |
Copyright | |
Other editions - View all
Common terms and phrases
additional aisle Allowable applied approved assembly backing Building Official building or structure ceiling cement cent Chapter chimney coat concrete conform construction Continued corridors covering defined designed Division doors Edition enclosed Enclosure exceed EXCEPTION exit exterior walls finish Fire Zone fire-resistive construction floor floor area foot foundation four framing gauge grade ground Group grout gypsum height horizontal hour inches incombustible increased installed interior joints lath least less limits located masonry materials maximum metal nails occupant load one-hour openings partitions permitted persons placed plaster portion pounds protected repair resistance roof seats separation serving sheathing side solid space spans Special specified in Section square feet Stairs stairway Standard stands story structure studs supports surface Table thereof thickness tion Type Uniform Building Code units unless veneer Ventilation vertical Volume wallboard width wire wood