Page 84
... one - half inch ( 1⁄2 " ) thick com- plying with U.B.C. Standard No. 22-1-67 . Plywood not less than five - sixteenths inch ( " ) thick complying with U.B.C. Standard No. 25-9-67 except as required by Section 2507 ( f ) 3 , 1967 Edition ...
... one - half inch ( 1⁄2 " ) thick com- plying with U.B.C. Standard No. 22-1-67 . Plywood not less than five - sixteenths inch ( " ) thick complying with U.B.C. Standard No. 25-9-67 except as required by Section 2507 ( f ) 3 , 1967 Edition ...
Page 114
... ( Inch ) PLANE OF FRAMING SURFACE LONG DIMENSION OF GYPSUM WALLBOARD SHEETS IN RELATION TO DIRECTION OF FRAMING ... one and five - eighths inches ( 15 % " ) long , fifteen - sixty- fourths - inch ( 1 " ) head for one - half - inch ( 12 ...
... ( Inch ) PLANE OF FRAMING SURFACE LONG DIMENSION OF GYPSUM WALLBOARD SHEETS IN RELATION TO DIRECTION OF FRAMING ... one and five - eighths inches ( 15 % " ) long , fifteen - sixty- fourths - inch ( 1 " ) head for one - half - inch ( 12 ...
Page 128
... one- half inches ( 31⁄2 " ) . ( c ) Rise and Run . The rise of every step in ... inch ( 1 " ) . EXCEPTION : In private stairways serving an occupant load of ... one flight between landings shall have identical dimensions within a three ...
... one- half inches ( 31⁄2 " ) . ( c ) Rise and Run . The rise of every step in ... inch ( 1 " ) . EXCEPTION : In private stairways serving an occupant load of ... one flight between landings shall have identical dimensions within a three ...
Contents
Part Administrative | 11 |
Part IIDefinitions and Abbreviations | 20 |
Part IIIRequirements Based on Occupancy | 27 |
Copyright | |
1 other sections not shown
Other editions - View all
Common terms and phrases
additional aisle Allowable applied approved assembly backing Building Official building or structure ceiling cement cent Chapter chimney coat concrete conform construction Continued corridors covering defined designed Division doors Edition enclosed Enclosure exceed EXCEPTION exit exterior walls finish Fire Zone fire-resistive construction floor floor area foot foundation four framing gauge grade ground Group grout gypsum height horizontal hour inches incombustible increased installed interior joints lath least less limits located masonry materials maximum metal nails occupant load one-hour openings partitions permitted persons placed plaster portion pounds protected repair resistance roof seats separation serving sheathing side solid space spans Special specified in Section square feet Stairs stairway Standard stands story structure studs supports surface Table thereof thickness tion Type Uniform Building Code units unless veneer Ventilation vertical Volume wallboard width wire wood