Uniform Building Code, Volume 7International Conference of Building Officials, 1967 - Building laws |
From inside the book
Results 1-3 of 38
Page 28
Mixed ( c ) Types of Occupancy Separation . Occupancy separations Occupancy
shall be classed as “ Four - Hour Fire - Resistive , ” “ Three - Hour Fire( Continued
) Resistive , ” “ Two - Hour Fire - Resistive , ” and “ One - Hour Fire - Resistive .
Mixed ( c ) Types of Occupancy Separation . Occupancy separations Occupancy
shall be classed as “ Four - Hour Fire - Resistive , ” “ Three - Hour Fire( Continued
) Resistive , ” “ Two - Hour Fire - Resistive , ” and “ One - Hour Fire - Resistive .
Page 36
Allowable Floor Areas ( Continued ) ( Continued from page 29 ) rior wall at the
termination of the area separation wall and the projecting elements above are not
less than one - hour fire - resistive construction for a width equal to the depth of ...
Allowable Floor Areas ( Continued ) ( Continued from page 29 ) rior wall at the
termination of the area separation wall and the projecting elements above are not
less than one - hour fire - resistive construction for a width equal to the depth of ...
Page 43
Exterior walls or parts of walls which are less than three feet ( 3 ' ) from adjacent
property lines shall have no openings therein and shall be of not less than one -
hour fire - resistive construction as specified in Chapter 43 of the 1967 Edition of
...
Exterior walls or parts of walls which are less than three feet ( 3 ' ) from adjacent
property lines shall have no openings therein and shall be of not less than one -
hour fire - resistive construction as specified in Chapter 43 of the 1967 Edition of
...
What people are saying - Write a review
We haven't found any reviews in the usual places.
Contents
Part Administrative | 11 |
Part 11Definitions and Abbreviations | 20 |
Part IIlRequirements Based on Occupancy | 27 |
Copyright | |
Other editions - View all
Common terms and phrases
additional aisle Allowable applied approved assembly backing Building Official building or structure ceiling cement cent Chapter chimney coat concrete conform construction Continued corridors covering defined designed Division doors Edition enclosed Enclosure exceed EXCEPTION exit exterior walls finish Fire Zone fire-resistive construction floor floor area foot foundation four framing gauge grade ground Group grout gypsum height horizontal hour inches incombustible increased installed interior joints lath least less limits located masonry materials maximum metal nails occupant load one-hour openings partitions permitted persons placed plaster portion pounds protected repair resistance roof seats separation serving sheathing side solid space spans Special specified in Section square feet Stairs stairway Standard stands story structure studs supports surface Table thereof thickness tion Type Uniform Building Code units unless veneer Ventilation vertical Volume wallboard width wire wood