Uniform Building Code, Volume 7International Conference of Building Officials, 1967 - Building laws |
From inside the book
Results 1-3 of 40
Page 28
... Hour Fire- Resistive , " " Two - Hour Fire - Resistive , " and " One - Hour Fire - Resis- tive . " ( See U.B.C. Standard No. 30-1-67 for fire dampers in air ducts piercing occupancy separations . ) 1. A " Four - Hour Fire - Resistive ...
... Hour Fire- Resistive , " " Two - Hour Fire - Resistive , " and " One - Hour Fire - Resis- tive . " ( See U.B.C. Standard No. 30-1-67 for fire dampers in air ducts piercing occupancy separations . ) 1. A " Four - Hour Fire - Resistive ...
Page 36
... hour fire - resistive construction . 2. Two - hour area separation walls may terminate at the underside of roof sheathing provided that the roof has at least one - hour fire - resistive time period for a width of not less than five feet ...
... hour fire - resistive construction . 2. Two - hour area separation walls may terminate at the underside of roof sheathing provided that the roof has at least one - hour fire - resistive time period for a width of not less than five feet ...
Page 43
... One - story buildings of Type III - one hour , IV - one hour or V - one hour construction may be permitted provided the floor area does not exceed thirty - nine hundred square feet ( 3900 sq . ft . ) between separation walls of two- hour ...
... One - story buildings of Type III - one hour , IV - one hour or V - one hour construction may be permitted provided the floor area does not exceed thirty - nine hundred square feet ( 3900 sq . ft . ) between separation walls of two- hour ...
Contents
Part Administrative | 11 |
Part IIDefinitions and Abbreviations | 20 |
Part IIIRequirements Based on Occupancy | 27 |
Copyright | |
1 other sections not shown
Other editions - View all
Common terms and phrases
aisle applied approved Area Allowable Building Official building or structure cavity walls cent Chapter 23 coat combustible conform Continued corbeled corridors exceed exit doors exterior exit balcony exterior walls feet Not permitted feet Protected less fire assembly Fire Zone Fire-extinguishing Systems fire-resistive rating fireplace Firestopping flammable liquids foot four inches gauge Group D Occupancies Group H grout Gypsum Lath gypsum wallboard H Occupancies horizontal hour less incombustible installed joists less than four Location on Property locking device Masonry chimneys materials maximum metal lath minimum nails occupant load one-hour fire-resistive construction partitions permitted less portion thereof portland cement plaster pounds per square ramp seats sheathing shingles soffits space spans Special Hazards specified in Chapter specified in Section Stairs stairway stories in height studs supports surface Table thickness tion toilet twelve inches 12 types of construction U.B.C. Standard Uniform Building Code veneer Ventilation Vertical Openings Wood shingles