Uniform Building Code, Volume 7International Conference of Building Officials, 1967 - Building laws |
From inside the book
Results 1-3 of 29
Page 28
... Hour Fire - Resistive , " " Three - Hour Fire- Resistive , " " Two - Hour Fire - Resistive , " and " One - Hour Fire - Resis- tive . " ( See U.B.C. Standard No. 30-1-67 for fire dampers in air ducts piercing occupancy separations . ) 1. A " ...
... Hour Fire - Resistive , " " Three - Hour Fire- Resistive , " " Two - Hour Fire - Resistive , " and " One - Hour Fire - Resis- tive . " ( See U.B.C. Standard No. 30-1-67 for fire dampers in air ducts piercing occupancy separations . ) 1. A " ...
Page 36
... one - hour fire - resistive construction for a width equal to the depth of the projecting ele- ments . Wall openings within such widths shall be protected by not less than three - fourths - hour fire - resistive assemblies . 3. Area ...
... one - hour fire - resistive construction for a width equal to the depth of the projecting ele- ments . Wall openings within such widths shall be protected by not less than three - fourths - hour fire - resistive assemblies . 3. Area ...
Page 39
... one - hour fire - resistive protection . Division 3 Occupancies located in a basement or above the first story shall be of not less than one - hour fire - resistive construction . Group B assembly rooms having an occupant load of 1000 ...
... one - hour fire - resistive protection . Division 3 Occupancies located in a basement or above the first story shall be of not less than one - hour fire - resistive construction . Group B assembly rooms having an occupant load of 1000 ...
Contents
Part IAdministrative | 11 |
Part IIDefinitions and Abbreviations | 20 |
Part IIIRequirements Based on Occupancy | 27 |
Copyright | |
Other editions - View all
Common terms and phrases
aisle applied approved Area Allowable Building Official building or structure cavity walls cent Chapter 23 coat combustible conform Continued corbeled corridors exceed exit doors exterior exit balcony exterior walls feet 1 hour feet Not permitted feet Protected less fire assembly Fire Zone Fire-extinguishing Systems fire-resistive rating fireplace Firestopping flammable liquids foot four inches G Occupancies gauge Group D Occupancies Group H grout Gypsum Lath gypsum wallboard horizontal hour less incombustible installed joists less than four Location on Property locking device Masonry chimneys materials maximum metal lath minimum nails occupant load one-hour fire-resistive construction partitions permitted less portion thereof pounds per square ramp seats sheathing shingles soffits space spans Special Hazards specified in Chapter specified in Section Stairs stairway stories in height studs supports surface Table thickness tion toilet twelve inches 12 types of construction U.B.C. Standard Uniform Building Code veneer Ventilation Vertical Openings Wood shingles