Uniform Building Code, Volume 7International Conference of Building Officials, 1967 - Building laws |
From inside the book
Results 1-3 of 6
Page 65
... panels . 2. In back - plastered construction . 3. When there is no human occupancy . 4. Over water - repellent panel sheathing . 5. Under approved paperbacked metal or wire fabric lath . 6. Under metal lath , wire lath , or wire fabric ...
... panels . 2. In back - plastered construction . 3. When there is no human occupancy . 4. Over water - repellent panel sheathing . 5. Under approved paperbacked metal or wire fabric lath . 6. Under metal lath , wire lath , or wire fabric ...
Page 67
... Panels . Doors and panels of shower and bathtub enclosures shall be substantially constructed from approved shatter- resistant materials . Hinged shower doors shall open outward . ( d ) Glass . Glass used in doors and panels of shower ...
... Panels . Doors and panels of shower and bathtub enclosures shall be substantially constructed from approved shatter- resistant materials . Hinged shower doors shall open outward . ( d ) Glass . Glass used in doors and panels of shower ...
Page 84
... PANEL IDENTIFICATION Maximum Span LOAD ( IN POUNDS PER INDEX3 ( in Inches ) SQUARE FOOT ) FLOOR Maximum Edges Edges Total Live Span4 Blocked Unblocked Load Load ( in inches ) 12/0 12 130 100 0 16/0 16 75 55 0 20/0 20 55 45 0 24/0 24 16 ...
... PANEL IDENTIFICATION Maximum Span LOAD ( IN POUNDS PER INDEX3 ( in Inches ) SQUARE FOOT ) FLOOR Maximum Edges Edges Total Live Span4 Blocked Unblocked Load Load ( in inches ) 12/0 12 130 100 0 16/0 16 75 55 0 20/0 20 55 45 0 24/0 24 16 ...
Contents
Part Administrative | 11 |
Part IIDefinitions and Abbreviations | 20 |
Part IIIRequirements Based on Occupancy | 27 |
Copyright | |
1 other sections not shown
Other editions - View all
Common terms and phrases
additional aisle Allowable applied approved assembly backing Building Official building or structure ceiling cement cent Chapter chimney coat concrete conform construction Continued corridors covering defined designed Division doors Edition enclosed Enclosure exceed EXCEPTION exit exterior walls finish Fire Zone fire-resistive construction floor floor area foot foundation four framing gauge grade ground Group grout gypsum height horizontal hour inches incombustible increased installed interior joints lath least less limits located masonry materials maximum metal nails occupant load one-hour openings partitions permitted persons placed plaster portion pounds protected repair resistance roof seats separation serving sheathing side solid space spans Special specified in Section square feet Stairs stairway Standard stands story structure studs supports surface Table thereof thickness tion Type Uniform Building Code units unless veneer Ventilation vertical Volume wallboard width wire wood