Page 64
... Partitions . Regardless of the fire - resistive requirements for permanent partitions , partitions dividing portions of stores , offices , or similar places occupied by one tenant only , and which do not establish a corridor serving an ...
... Partitions . Regardless of the fire - resistive requirements for permanent partitions , partitions dividing portions of stores , offices , or similar places occupied by one tenant only , and which do not establish a corridor serving an ...
Page 73
... Partitions . 1. Placing . Studs in walls and partitions may be placed with their wide faces parallel to the wall or partition , provided the studs are considered as columns and are designed accordingly . Stud walls shall have top and ...
... Partitions . 1. Placing . Studs in walls and partitions may be placed with their wide faces parallel to the wall or partition , provided the studs are considered as columns and are designed accordingly . Stud walls shall have top and ...
Page 74
... partitions containing plumbing , heating , or other pipes shall be so framed and the joists underneath so spaced as to give proper clearance for the piping . Where a partition containing such piping runs parallel to the floor joists ...
... partitions containing plumbing , heating , or other pipes shall be so framed and the joists underneath so spaced as to give proper clearance for the piping . Where a partition containing such piping runs parallel to the floor joists ...
Contents
Part Administrative | 11 |
Part IIDefinitions and Abbreviations | 20 |
Part IIIRequirements Based on Occupancy | 27 |
Copyright | |
1 other sections not shown
Other editions - View all
Common terms and phrases
additional aisle Allowable applied approved assembly backing Building Official building or structure ceiling cement cent Chapter chimney coat concrete conform construction Continued corridors covering defined designed Division doors Edition enclosed Enclosure exceed EXCEPTION exit exterior walls finish Fire Zone fire-resistive construction floor floor area foot foundation four framing gauge grade ground Group grout gypsum height horizontal hour inches incombustible increased installed interior joints lath least less limits located masonry materials maximum metal nails occupant load one-hour openings partitions permitted persons placed plaster portion pounds protected repair resistance roof seats separation serving sheathing side solid space spans Special specified in Section square feet Stairs stairway Standard stands story structure studs supports surface Table thereof thickness tion Type Uniform Building Code units unless veneer Ventilation vertical Volume wallboard width wire wood